ISBM Machine Troubleshooting — 12 Common Blow Moulding Defects, Causes, and Fixes
Every ISBM machine operator encounters the same defects — often at the worst possible moment: at the start of a production run, in the middle of a shift, or when a customer’s quality team is due for an incoming inspection the next morning. The difference between an experienced process engineer and a novice operator is not that the engineer never sees these blow moulding defects — it is that the engineer knows immediately which parameter to change and by how much.
Das ISBM machine troubleshooting guide addresses the most common PET bottle defects Und blow moulding problems and solutions encountered in daily production — including injection blow moulding defects that originate at the injection station, and blow-station defects that originate in conditioning or blow parameter settings. It is organised by the symptom the operator observes in the finished bottle, not by the machine component that is involved. Each defect has a structured entry covering: what the defect looks like, which root causes produce it, which one to check first (the most likely cause), and the specific parameter adjustment or maintenance action that resolves it. A quick-reference table at the top allows experienced operators to locate defects rapidly; the detailed entries below provide the full diagnostic context for each.
Quick Reference — 12 ISBM Defects at a Glance

How to Use This Guide
Observe the defect in the bottle or preform → locate the defect number in the quick-reference table → read the “Check First” column for the most likely cause → jump to the detailed entry below for root cause analysis and specific parameter corrections. If the first correction does not resolve the defect, work through the secondary causes listed in the detailed entry. For a deeper understanding of how the ISBM process produces quality bottles, see our guide to what is injection stretch blow moulding.
Defect 1 — Uneven Wall Thickness
Diagnosis and Fix: Check the conditioning station barrel temperature at four angular positions (0°, 90°, 180°, 270°) using a contact pyrometer on the preform surface immediately before the blow station. A temperature difference of more than 3–5 °C between positions indicates a conditioning barrel problem — either uneven heating element output, poor barrel-to-preform contact, or a fluid flow restriction in one zone of the barrel circuit. Balance the barrel temperature by adjusting zone setpoints until circumferential variation is below 2 °C. If the temperature is uniform but wall thickness is still asymmetric, check core pin concentricity: remove a preform before blowing and measure wall thickness at four points with a caliper — if the preform itself is eccentric, the core pin or cavity alignment is the root cause, requiring tooling inspection.
Defect 2 — Bottle Haze (Loss of Clarity)
Fix by resin: For PETG, raise the conditioning barrel setpoint by 3–5 °C and verify the actual preform body temperature reaches 92–96 °C before the blow station. For PET haze at the base, lower the gate zone conditioning temperature by 3 °C (the base is typically the last zone to cool and can over-crystallise). For blow-back mat marks, deepen parting-line vent slots to 0.02 mm and add vent pins at affected zones. For mould cooling issues, reduce cooling water supply temperature to 8–12 °C and verify flow rate.
Defect 3 — Flash at the Parting Line
Fix: First, verify the blow clamp pressure on the machine gauge against the specification for the installed mould (typically 60–100 kN for standard ISBM blow moulds). If pressure is correct, inspect the parting line faces of both cavity halves for damage — a nick or raised burr on either face will prevent full sealing regardless of clamping force. Parting line damage requires re-polishing or re-grinding the affected face by a toolmaker. If both clamp and parting line are correct, check that the mould is seating fully in the blow station by measuring the gap between mould blocks with a feeler gauge at four points on a manually clamped (no blow pressure) cycle.
Defect 4 — Short Shot (Incomplete Preform Fill)
Fix: Weigh preforms from the affected cavity and compare to the specification. If all cavities are light, increase injection volume (screw recovery position) by 2–3 mm and recheck. If one cavity is consistently light in a multi-cavity tool, check the hot runner balance: measure individual cavity gate temperatures with an infrared pyrometer and equalise within ±2 °C. For a resin moisture problem, verify the hopper dryer outlet dew point (should be below −40 °C) and material temperature (65 °C for PET, 80 °C for Tritan). After correcting moisture, purge 3–5 shots before accepting production.

Defect 5 — Stress Whitening (Crazing)
Fix: The correction priority is temperature first. Raise the conditioning station setpoint for the body zone by 3–5 °C (PET: target 108–112 °C; PETG: 93–97 °C) and produce a trial batch. If stress whitening persists but is reduced, continue raising temperature in 2 °C increments until it disappears. If temperature adjustment does not help, reduce stretch rod speed by 10–15% — a slower rod descent gives the preform more time to deform plastically rather than fracturing. If stress whitening only occurs at the shoulder, the preform’s upper body wall may be too thin; the mould DFM should be reviewed with the toolmaker.
Defect 6 — Bubbles or Voids in the Preform Wall
Fix: Bubbles and splay are almost always a moisture problem. Immediately check: (a) hopper dryer setpoint is at the correct temperature for the resin (65 °C for PET, 80 °C for Tritan, 120 °C for PC); (b) drying time has been met (minimum 4 hours for all resins); (c) the desiccant in the dryer is not saturated — confirm outlet dew point is below −40 °C with a dew point meter, not by assuming. If moisture is confirmed as the cause, extend the drying time to 6 hours before next production run. If drying conditions are correct and bubbles persist, reduce barrel zone temperatures by 5 °C across all zones and check for degraded material in the screw flights by performing a purge.
Defect 7 — Base Pearlescence (Halo Effect)
Fix: Raise the gate zone conditioning temperature by 3–5 °C above the body zone setpoint (not the body zone — the gate zone specifically, which has its own setpoint on dual-zone conditioning systems). Additionally, verify that the stretch rod is reaching its full travel position — if the rod stops short of the gate dome contact point, the gate zone receives no mechanical stretch and will always pearl regardless of conditioning temperature. Confirm rod travel with a measurement check at the blow station with the mould closed but no blow pressure. If the base pearlescence persists after temperature and rod travel corrections, the preform’s gate dome wall thickness may be insufficient for adequate heat penetration — review the preform design with the mould supplier.
Defect 8 — Neck Finish Dimensional Drift
Fix: First, check the neck cooling water flow at the mould outlet — it should be flowing at 2–4 L/min at 8–15 °C. A restricted or partially blocked neck cooling circuit is the most common cause of progressive neck drift across a shift, because the neck ring temperature rises slowly as mould cycling heats the tooling and the restricted circuit cannot extract heat fast enough. If flow is correct, gauge the neck ring tooling: use a calibrated thread gauge and neck OD gauge to check whether the tooling dimensions are within tolerance. Neck ring replacement is the correction for worn tooling — there is no process adjustment that compensates for a neck ring that is below its minimum gauge dimension.

Defect 9 — Hot-Fill Bottle Deformation After Filling
Fix: First, confirm the blow mould oil heater is maintaining 120–150 °C at the mould inlet. If the mould temperature is correct, extend the heat-set dwell time from its current value to at least 2.5 seconds and re-run a trial batch. Measure wall crystallinity by DSC (differential scanning calorimetry) — it should be 20–30% in the bottle body wall after heat-setting. If crystallinity is below 20% with correct mould temperature and dwell time, the resin IV is likely the problem — switch to a hot-fill grade resin with IV 0.80–0.85 dl/g. Note that if a standard HGS-A model is being used instead of the HGS200B, the stretching stroke may be insufficient to achieve the axial orientation depth required for hot-fill crystallinity regardless of all other parameters — this is not a process parameter problem, it is a machine specification mismatch.
Defect 10 — Take-Out / Ejection Failure
Fix: Check the mould open stroke programmed value against the bottle body height plus 20 mm minimum clearance. If the stroke is correct, measure the bottle surface temperature on ejection — it should be below 60 °C for standard PET (below TGEine Oberflächentemperatur über 65 °C deutet auf unzureichende Kühlung hin; reduzieren Sie die Kühlwassertemperatur oder verlängern Sie die Schließzeit der Form. Tritt das Problem nur sporadisch auf, könnte dies an der Steuerung des Auslassventils liegen – der Blasdruck muss vollständig abgebaut sein, bevor sich die Form öffnet; prüfen Sie, ob das Auslassventil im Zyklus an den richtigen Positionen öffnet und schließt.
Fehler 11 – Vergilbung in Tritan- oder PC-Flaschen
Fix: Prüfen Sie die Ist-Temperatur jeder Zylinderzone anhand des Sollwerts auf dem HMI. Eine Zone, die 5 °C oder mehr über dem Sollwert liegt, deutet auf eine fehlerhafte Heizungsregelung hin – prüfen Sie das Thermoelement, den PID-Reglerausgang und die Durchgängigkeit des Heizelements. Liegen alle Zonen innerhalb des Sollbereichs, untersuchen Sie die Verweilzeit: Zählen Sie die Maschinenzyklen während des letzten Produktionsstopps von mehr als 5 Minuten und vergleichen Sie diese mit dem typischen Spülzyklus. Bei Tritan erfordert jeder Stopp von mehr als 10 Minuten bei Verarbeitungstemperatur eine Spülung mit 3–5 Schüssen, bevor die Produktion wieder aufgenommen wird. Erstellen Sie für die Stilllegung eine schriftliche Standardarbeitsanweisung (SOP), die eine vollständige Zylinderspülung mit neutralem PET vor jedem geplanten Stillstand vorschreibt. Spülen Sie nach einem nächtlichen Stillstand bei Tritan 8–10 Schüsse, bevor Sie die Produktion annehmen, und prüfen Sie die Farbe des Spülmaterials anhand der Spezifikationsfarbe.
Fehler 12 – Inkonsistente Zykluszeit
Fix: Bei hydraulischen Maschinen ist die Hydrauliköltemperaturanzeige zu überwachen und sicherzustellen, dass sie sich im Betriebsbereich von 40–50 °C befindet, bevor die Produktion aufgenommen wird. Ist die Öltemperatur beim Anlauf zu niedrig, sollte die Maschine 10–15 Minuten im manuellen Zyklusmodus (ohne Einspritzung) laufen gelassen werden, um das Öl vor Produktionsbeginn aufzuwärmen. Bei vollelektrischen Maschinen – die kein Hydrauliköl verwenden – sind Schwankungen der Zykluszeit fast immer auf Temperaturdrift oder die Anlaufzeit der Einspritzschnecke zurückzuführen. Die Anlaufzeit der Einspritzschnecke ist am HMI zu überwachen: Sie sollte innerhalb von ±0,2 Sekunden pro Zyklus konstant sein. Bei größeren Schwankungen ist der Trichter auf Brückenbildung zu prüfen, der Gegendruck-Sollwert zu vergewissern, dass er sich nicht geändert hat, und die Schnecke auf Verschleiß zu untersuchen, falls das Problem weiterhin besteht. HGY50-V3-EV vollelektrische Maschine Die Hydrauliköltemperatur wird als Variable vollständig eliminiert – das Ansprechverhalten des Servomotors ist vom Kaltstart an konstant, wodurch die Zykluszeitstabilität im Mehrschichtbetrieb deutlich einfacher aufrechtzuerhalten ist.

◆ Wichtigstes Prinzip der Fehlerbehebung
Jeder Blasformfehler Der Fehler hat seinen Ursprung in einer Prozessstufe: Liegt der Fehler im Vorformling (Blasen, unvollständige Spritzung, Vergilbung), prüfen Sie die Spritzgießanlage. Befindet sich der Fehler im geblasenen Flaschenkörper (Trübung, Spannungsaufhellung, Wandstärkenabweichungen, Perlglanz), prüfen Sie die Konditionierung und die Parameter der Blasstation. Liegt der Fehler im Flaschenhals, prüfen Sie die Spritzgießkühlung und den Zustand des Flaschenhalsrings. Nehmen Sie jeweils nur eine Änderung vor, produzieren Sie zwischen den Änderungen 20–30 Flaschen und dokumentieren Sie die Änderung und das Ergebnis. Ein Fehlerprotokoll über mehrere Schichten hinweg ist wertvoller als jede einzelne Fehlerbehebung – Muster, die in einem einzelnen Produktionslauf nicht erkennbar sind, werden durch systematische Aufzeichnungen über eine Woche hinweg deutlich.
Abschluss
Die 12 blow moulding defects Dieser Leitfaden behandelt die meisten Qualitätsprobleme, die in ISBM-Produktionslinien auftreten. Die meisten lassen sich durch Parameteranpassungen innerhalb weniger Minuten beheben; einige wenige erfordern eine Werkzeugprüfung oder einen Werkzeugaustausch, was Stunden in Anspruch nimmt. Die wichtigste Disziplin für einen ISBM-Bediener ist die Gewohnheit, jeweils eine Variable in der Reihenfolge ihrer wahrscheinlichsten Ursache zu überprüfen und das Ergebnis zu dokumentieren, bevor er zur nächsten übergeht. Erfahrene Verfahrenstechniker lösen diese Probleme schnell, nicht weil sie Zauberlösungen kennen, sondern weil sie systematisch vorgehen und dokumentiert haben, was funktioniert.
Korea Ever-Power's ISBM-Maschinen der HGY-Serie mit 3 Stationen Sie erhalten umfassende Unterstützung bei der Inbetriebnahme sowie eine Prozessdokumentation, die die Basisparameter für jedes Containerprogramm festlegt. So haben die Betreiber einen dokumentierten Ausgangspunkt für die Fehlersuche und sind nicht auf informelle Wissensvermittlung angewiesen. Kontaktieren Sie das technische Supportteam von Korea Ever-Power für anwendungsspezifische Unterstützung bei der Fehlerdiagnose an installierten Maschinen.
Über diesen Artikel: Diese Informationen wurden vom technischen Team von Korea Ever-Power auf Basis von Serviceberichten aus dem Außendienst, Inbetriebnahmeprotokollen und verfahrenstechnischer Erfahrung mit Anlagen der Serien HGY und HGS erstellt. Die Temperaturvorgaben und Parameterbereiche dienen als Richtlinien für Standard-PET und PETG in Flaschenqualität; spezifische Harze, Preform-Designs und Kavitätenkonfigurationen können abweichende Sollwerte erfordern, die während der Inbetriebnahme festgelegt werden.
Weiterführende Lektüre: Biaxiale Orientierung in PET-Flaschen – Wie ISBM dies erreicht | ISBM-Werkzeugkonstruktion – Vorformling, Blasformkavität und Kernstift | Was ist Spritzstreckblasformen? – Prozessleitfaden
Herausgeber: Cxm