{"id":1090,"date":"2026-07-06T06:11:39","date_gmt":"2026-07-06T06:11:39","guid":{"rendered":"https:\/\/isbm-blow-molding.com\/?p=1090"},"modified":"2026-07-06T06:11:39","modified_gmt":"2026-07-06T06:11:39","slug":"korean-kfda-gmp-pharmaceutical-ibm","status":"publish","type":"post","link":"https:\/\/isbm-blow-molding.com\/fr\/korean-kfda-gmp-pharmaceutical-ibm\/","title":{"rendered":"Guide des bonnes pratiques de fabrication (BPF) pour les conteneurs pharmaceutiques IBM de la KFDA cor\u00e9enne"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><!-- \u2550\u2550 HERO \u2550\u2550 --><\/p>\n<header style=\"position: relative; min-height: min(600px,88vh); display: flex; align-items: flex-end; width: 100%; background: #06100e; background-image: linear-gradient(155deg,rgba(4,12,10,0.97) 0%,rgba(8,24,20,0.93) 52%,rgba(14,66,50,0.65) 100%),url('https:\/\/isbm-blow-molding.com\/wp-content\/uploads\/2026\/07\/IBM-mold-3.webp'); background-size: cover; background-position: center 35%;\">\n<div style=\"position: absolute; top: 0; left: 0; right: 0; height: 5px; background: linear-gradient(90deg,#d97706,#f59e0b,#d97706);\"><\/div>\n<div style=\"position: absolute; bottom: -1px; left: 0; right: 0; height: 56px; background: #f0f3f7; clip-path: polygon(0 100%,100% 100%,100% 0);\"><\/div>\n<div style=\"position: relative; z-index: 2; width: 100%; padding: clamp(48px,7vw,96px) clamp(20px,5vw,60px) clamp(52px,6vw,84px); box-sizing: border-box;\">\n<div style=\"display: inline-flex; align-items: center; gap: 8px; margin-bottom: 20px;\">\n<div style=\"width: 28px; height: 3px; background: #d97706;\"><\/div>\n<p><span style=\"font-size: 10px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #f59e0b;\">GUIDE R\u00c9GLEMENTAIRE \u00b7 BPF KFDA COR\u00c9ENNE \u00b7 IBM PHARMACEUTICAL \u00b7 EVER-POWER COR\u00c9E<\/span><\/p>\n<div style=\"width: 28px; height: 3px; background: #d97706;\"><\/div>\n<\/div>\n<h1 style=\"font-size: clamp(26px,4.6vw,46px); font-weight: 900; color: #fff; line-height: 1.1; margin: 0 0 20px; letter-spacing: -0.8px; max-width: 720px;\">KFDA cor\u00e9en IBM<br \/>\nConteneur pharmaceutique<br \/>\n<span style=\"color: #f59e0b;\">Guide des BPF<\/span><\/h1>\n<p style=\"font-size: clamp(14px,1.9vw,17px); color: #94a3b8; line-height: 1.7; margin: 0 0 30px; max-width: 600px;\">La qualification BPF (Bonnes Pratiques de Fabrication) des contenants pharmaceutiques par la KFDA cor\u00e9enne est une \u00e9tape cruciale de tout projet d'emballage pharmaceutique IBM en Cor\u00e9e. Son d\u00e9lai de r\u00e9alisation est sup\u00e9rieur \u00e0 celui de la fabrication des machines ou des moules, et il est ind\u00e9pendant des d\u00e9lais de livraison de Korea Ever-Power. Ce guide d\u00e9crit l'int\u00e9gralit\u00e9 du cadre de qualification KFDA pour les contenants IBM en PEHD et PP\u00a0: exigences documentaires, sp\u00e9cifications des tests de la Pharmacop\u00e9e cor\u00e9enne, dur\u00e9e de l'\u00e9tude des substances extractibles, qualification de la fonction de fermeture et proc\u00e9dure de notification des modifications en cas de changement du nombre de cavit\u00e9s ou du lot de r\u00e9sine.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 6px;\"><span style=\"background: rgba(217,119,6,0.15); border: 1px solid rgba(217,119,6,0.45); color: #fbbf24; font-size: 11px; font-weight: bold; padding: 4px 12px; border-radius: 2px; letter-spacing: 1px; text-transform: uppercase;\">Exigences du test KP cor\u00e9en<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.06); border: 1px solid rgba(255,255,255,0.15); color: #94a3b8; font-size: 11px; font-weight: bold; padding: 4px 12px; border-radius: 2px; letter-spacing: 1px; text-transform: uppercase;\">Substances extractibles \/ lixiviables<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.06); border: 1px solid rgba(255,255,255,0.15); color: #94a3b8; font-size: 11px; font-weight: bold; padding: 4px 12px; border-radius: 2px; letter-spacing: 1px; text-transform: uppercase;\">Notification de modification de la KFDA<\/span><\/div>\n<p style=\"font-size: 11px; color: #475569; margin: 22px 0 0; letter-spacing: 1px;\">COR\u00c9E EVER-POWER \u00b7 ANSAN-SI, GYEONGGI-DO \u00b7 JUILLET 2026<\/p>\n<\/div>\n<\/header>\n<p>&nbsp;<\/p>\n<p><!-- SPEC PANEL --><\/p>\n<div style=\"background: #0f1e35; border: 1px solid #1e3a5f; border-left: 4px solid #d97706; border-radius: 4px; padding: 24px 28px; margin: 52px 0 0;\">\n<div style=\"display: flex; align-items: center; gap: 10px; margin-bottom: 18px;\">\n<div style=\"width: 16px; height: 16px; border: 2px solid #d97706; border-radius: 50%; display: flex; align-items: center; justify-content: center; flex-shrink: 0;\">\n<div style=\"width: 6px; height: 6px; background: #d97706; border-radius: 50%;\"><\/div>\n<\/div>\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0;\">R\u00c9F\u00c9RENCE SYST\u00c8ME \u00b7 PARAM\u00c8TRES DE QUALIFICATION PHARMACEUTIQUES IBM (KFDA COR\u00c9ENNE)<\/p>\n<\/div>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(min(100%,170px),1fr)); gap: 1px; background: #1e3a5f;\">\n<div style=\"background: #0f1e35; padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #475569; margin: 0 0 6px;\">DUR\u00c9E DU CHEMIN CRITIQUE<\/p>\n<p style=\"font-size: 26px; font-weight: 900; color: #f59e0b; margin: 0 0 4px; font-variant-numeric: tabular-nums;\">24 semaines<\/p>\n<p style=\"font-size: 12px; color: #64748b; margin: 0;\">Minimum entre le premier \u00e9chantillon de production IBM et la documentation de qualification compl\u00e8te<\/p>\n<\/div>\n<div style=\"background: #0f1e35; padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #475569; margin: 0 0 6px;\">EXAMEN DES MODIFICATIONS DE LA KFDA<\/p>\n<p style=\"font-size: 26px; font-weight: 900; color: #f59e0b; margin: 0 0 4px; font-variant-numeric: tabular-nums;\">3 \u00e0 6 mois<\/p>\n<p style=\"font-size: 12px; color: #64748b; margin: 0;\">Calendrier d'examen des notifications de changement majeur \u2014 changement de machine, changement du nombre de cavit\u00e9s<\/p>\n<\/div>\n<div style=\"background: #0f1e35; padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #475569; margin: 0 0 6px;\">LIMITE DES EXTRACTIBLES KP<\/p>\n<p style=\"font-size: 26px; font-weight: 900; color: #f59e0b; margin: 0 0 4px; font-variant-numeric: tabular-nums;\">\u226430 ppm<\/p>\n<p style=\"font-size: 12px; color: #64748b; margin: 0;\">Limite de r\u00e9sidus d'\u00e9vaporation \u2014 milieu d'extraction : eau, acide ac\u00e9tique 4%, n-heptane<\/p>\n<\/div>\n<div style=\"background: #0f1e35; padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #475569; margin: 0 0 6px;\">\u00c9TUDE DE COMPATIBILIT\u00c9<\/p>\n<p style=\"font-size: 26px; font-weight: 900; color: #f59e0b; margin: 0 0 4px; font-variant-numeric: tabular-nums;\">12\/24 semaines<\/p>\n<p style=\"font-size: 12px; color: #64748b; margin: 0;\">Voie orale\u00a0: 12 semaines (proc\u00e9dure acc\u00e9l\u00e9r\u00e9e) \u00b7 Voie ophtalmique\u00a0: 24 semaines (p\u00e9riode critique la plus longue)<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- TOC --><\/p>\n<nav style=\"margin: 28px 0 0; background: #fff; border: 1px solid #cbd5e0; border-radius: 4px; padding: 22px 26px; position: relative; overflow: hidden;\">\n<div style=\"position: absolute; inset: 0; background-image: linear-gradient(rgba(30,58,95,0.03) 1px,transparent 1px),linear-gradient(90deg,rgba(30,58,95,0.03) 1px,transparent 1px); background-size: 24px 24px; pointer-events: none;\"><\/div>\n<div style=\"position: relative;\">\n<div style=\"display: flex; align-items: center; gap: 8px; margin-bottom: 14px;\">\n<div style=\"width: 3px; height: 14px; background: #d97706; border-radius: 2px;\"><\/div>\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 2.5px; text-transform: uppercase; color: #1e3a5f; margin: 0;\">INDEX DES DOCUMENTS<\/p>\n<\/div>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(min(100%,270px),1fr)); gap: 2px 24px;\"><a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s1\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">01<\/span>Cadre de conteneur pharmaceutique cor\u00e9en KFDA<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s2\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">02<\/span>S\u00e9lection de la machine et de la cavit\u00e9 IBM pour la qualification KFDA<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s3\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">03<\/span>Dossier technique du conteneur \u2014 Documentation requise<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s4\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">04<\/span>Tests des contenants en plastique de la Pharmacop\u00e9e cor\u00e9enne<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s5\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">05<\/span>\u00c9tudes de compatibilit\u00e9 et d'extractibles\/relargables<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s6\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">06<\/span>Qualification fonctionnelle et dimensionnelle de la fermeture<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s7\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">07<\/span>Processus de notification de changement de la KFDA cor\u00e9enne<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline; border-bottom: 1px solid #f1f5f9;\" href=\"#s8\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">08<\/span>Support de documentation GMP Ever-Power en Cor\u00e9e<\/a><br \/>\n<a style=\"color: #1e3a5f; text-decoration: none; font-size: 13.5px; padding: 4px 0; display: flex; align-items: baseline;\" href=\"#faq\"><span style=\"color: #d97706; font-size: 10px; font-weight: 800; margin-right: 8px; flex-shrink: 0;\">FAQ<\/span>Questions d'ing\u00e9nierie r\u00e9glementaire<\/a><\/div>\n<\/div>\n<\/nav>\n<p><!-- \u2550\u2550 S1 \u2550\u2550 --><\/p>\n<div style=\"padding: 0px 2%;\">\n<section id=\"s1\" style=\"margin: 64px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 01<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">Cadre r\u00e9glementaire cor\u00e9en des contenants pharmaceutiques de la KFDA<\/h2>\n<\/div>\n<\/div>\n<figure style=\"margin: 0 0 24px;\"><img decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 3px; display: block; border: 1px solid #cbd5e0;\" title=\"Qualification GMP des conteneurs IBM par la KFDA (autorit\u00e9 cor\u00e9enne de r\u00e9glementation pharmaceutique)\" src=\"https:\/\/isbm-blow-molding.com\/wp-content\/uploads\/2026\/07\/Pharmaceutical-Bottles.webp\" alt=\"Qualification des contenants pharmaceutiques IBM par la KFDA cor\u00e9enne \u2014 Contenants en PEHD pour solutions ophtalmiques et orales (m\u00e9dicaments CRC) n\u00e9cessitant la documentation de qualification des contenants pharmaceutiques selon les BPF de la KFDA cor\u00e9enne, ainsi qu&#039;une \u00e9tude de compatibilit\u00e9 des substances extractibles et relargables (tests de la Pharmacop\u00e9e cor\u00e9enne KP) pour les contenants en plastique.\" \/><figcaption style=\"font-size: 12px; color: #64748b; margin-top: 8px; padding-left: 10px; border-left: 2px solid #d97706;\">Les contenants primaires pharmaceutiques cor\u00e9ens IBM \u2014 formats ophtalmiques en PEHD, liquides oraux et m\u00e9dicaments CRC \u2014 n\u00e9cessitent chacun une qualification distincte de contenant pharmaceutique KFDA cor\u00e9enne qui comprend des tests de contenants en plastique KP cor\u00e9ens, la compatibilit\u00e9 chimique, des tests de fonction de fermeture et une documentation dimensionnelle pour toutes les cavit\u00e9s de production.<\/figcaption><\/figure>\n<p style=\"font-size: 16px; margin-bottom: 14px;\">La qualification des emballages primaires pharmaceutiques en Cor\u00e9e est r\u00e9gie par la loi cor\u00e9enne sur les affaires pharmaceutiques (\uc57d\uc0ac\ubc95, loi n\u00b0 18651), le r\u00e8glement cor\u00e9en relatif aux bonnes pratiques de fabrication (BPF) \u00e9dict\u00e9 par le minist\u00e8re de la S\u00e9curit\u00e9 alimentaire et pharmaceutique (MFDS\/KFDA, \uc2dd\ud488\uc758\uc57d\ud488\uc548\uc804\ucc98) et la Pharmacop\u00e9e cor\u00e9enne (KP, \ub300\ud55c\uc57d\uc804), qui contient la monographie relative aux emballages en plastique \u00e0 usage pharmaceutique. Ces trois instruments r\u00e9glementaires s'appliquent \u00e0 diff\u00e9rents niveaux\u00a0: la loi sur les affaires pharmaceutiques \u00e9tablit l'obligation de qualifier les emballages primaires\u00a0; le r\u00e8glement relatif aux BPF d\u00e9finit le syst\u00e8me qualit\u00e9 dans lequel la qualification des emballages doit \u00eatre r\u00e9alis\u00e9e et document\u00e9e\u00a0; et la monographie de la Pharmacop\u00e9e cor\u00e9enne relative aux emballages en plastique sp\u00e9cifie les tests chimiques et les limites que les emballages en PEHD ou PP IBM doivent respecter.<\/p>\n<p style=\"font-size: 16px; margin-bottom: 14px;\">Les emballages IBM constituent le conditionnement primaire des produits pharmaceutiques cor\u00e9ens, c'est-\u00e0-dire le mat\u00e9riau d'emballage en contact direct avec le produit. Cette classification les distingue des emballages secondaires (cartons ext\u00e9rieurs, cartons d'exp\u00e9dition) qui sont soumis uniquement aux normes cor\u00e9ennes g\u00e9n\u00e9rales relatives aux mat\u00e9riaux d'emballage, et non aux exigences compl\u00e8tes de qualification des emballages pharmaceutiques cor\u00e9ens. Le conditionnement primaire de chaque produit pharmaceutique cor\u00e9en est r\u00e9pertori\u00e9 dans le dossier produit enregistr\u00e9 aupr\u00e8s de la KFDA (Agence cor\u00e9enne des produits alimentaires et m\u00e9dicamenteux), avec son type de mat\u00e9riau, l'identit\u00e9 du fournisseur et ses sp\u00e9cifications dimensionnelles. Toute modification apport\u00e9e au conditionnement primaire apr\u00e8s l'enregistrement initial aupr\u00e8s de la KFDA requiert une notification de modification formelle \u2013 l'\u00e9quivalent cor\u00e9en d'une notification de modification post-autorisation \u2013 dont le d\u00e9lai d'examen (auto-d\u00e9claration pour les modifications mineures, 3 \u00e0 6 mois pour les modifications majeures) constitue souvent un \u00e9l\u00e9ment critique du processus de d\u00e9veloppement des emballages pharmaceutiques et de la gestion de la cha\u00eene d'approvisionnement en Cor\u00e9e.<\/p>\n<p style=\"font-size: 16px; margin-bottom: 0;\">Le contexte complet de l'IBM dans l'emballage pharmaceutique cor\u00e9en \u2014 formats de contenants, sp\u00e9cifications des mat\u00e9riaux PEHD et PP, exigences de production en salle blanche et s\u00e9lection des machines \u2014 est abord\u00e9 dans le guide IBM pharmaceutique. Ce guide se concentre sp\u00e9cifiquement sur le processus de qualification des BPF de la KFDA cor\u00e9enne que les producteurs cor\u00e9ens de contenants IBM doivent suivre, de la commande des machines \u00e0 l'approbation de la production commerciale.<\/p>\n<\/section>\n<p><!-- \u2550\u2550 S2 \u2550\u2550 --><\/p>\n<section id=\"s2\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 02<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">S\u00e9lection de la machine et de la cavit\u00e9 IBM pour la qualification KFDA cor\u00e9enne<\/h2>\n<\/div>\n<\/div>\n<figure style=\"margin: 0 0 24px;\"><img decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 3px; display: block; border: 1px solid #cbd5e0;\" title=\"Machine IBM s\u00e9rie ZQ \u2014 Qualification pharmaceutique KFDA cor\u00e9enne\" src=\"https:\/\/isbm-blow-molding.com\/wp-content\/uploads\/2026\/07\/IBM-Internal-structure.webp\" alt=\"Structure interne de la machine IBM s\u00e9rie Ever-Power ZQ (Cor\u00e9e)\u00a0: identification du num\u00e9ro de s\u00e9rie pour la documentation de qualification des contenants pharmaceutiques KFDA (autorit\u00e9 cor\u00e9enne de r\u00e9glementation des m\u00e9dicaments), double syst\u00e8me hydraulique, configuration de zone de f\u00fbt 4+N pour la production de PEHD pharmaceutique.\" \/><figcaption style=\"font-size: 12px; color: #64748b; margin-top: 8px; padding-left: 10px; border-left: 2px solid #d97706;\">Machines de la s\u00e9rie Korea Ever-Power ZQ \u2014 chaque machine poss\u00e8de un num\u00e9ro de s\u00e9rie unique enregistr\u00e9 dans le dossier technique de qualification des contenants pharmaceutiques de la KFDA cor\u00e9enne. Ce num\u00e9ro de s\u00e9rie, associ\u00e9 au num\u00e9ro du moule et au nombre d'empreintes, constitue l'identifiant de l'\u00e9quipement de production, liant ainsi la qualification \u00e0 la configuration de production pr\u00e9cise. Toute modification ult\u00e9rieure de cette configuration requiert une notification de changement aupr\u00e8s de la KFDA cor\u00e9enne.<\/figcaption><\/figure>\n<p style=\"font-size: 16px; margin-bottom: 20px;\"><a href=\"https:\/\/isbm-blow-molding.com\/fr\/product-category\/injection-blow-molding-machine\/\">machine IBM<\/a> Le choix du mod\u00e8le ZQ pour la production pharmaceutique cor\u00e9enne est soumis \u00e0 une contrainte r\u00e9glementaire sp\u00e9cifique, diff\u00e9rente de celle applicable aux produits chimiques m\u00e9nagers ou cosm\u00e9tiques\u00a0: la qualification des contenants pharmaceutiques par la KFDA cor\u00e9enne identifie explicitement la machine de production par son num\u00e9ro de s\u00e9rie et le moule par le nombre d\u2019empreintes. Ainsi, le choix du mod\u00e8le ZQ lors de la commande de la machine ne se limite pas \u00e0 une simple d\u00e9cision de capacit\u00e9 de production\u00a0; il s\u2019agit d\u2019un engagement r\u00e9glementaire qui d\u00e9termine le calendrier de qualification et les obligations de notification de changement tout au long du cycle de vie commercial du produit.<\/p>\n<p><!-- KFDA lock-in matrix --><\/p>\n<div style=\"background: #0f1e35; border-radius: 4px; padding: 22px 26px; margin: 0 0 22px; border-top: 3px solid #d97706;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 16px;\">MATRICE DE VERROUILLAGE R\u00c9GLEMENTAIRE \u00b7 MOD\u00c8LE ZQ \u00d7 IMPACT DE LA QUALIFICATION KFDA<\/p>\n<div style=\"overflow-x: auto;\">\n<table style=\"width: 100%; border-collapse: collapse; font-size: 13px; min-width: 580px;\">\n<thead>\n<tr style=\"background: #1e3a5f;\">\n<th style=\"color: #f59e0b; padding: 10px 12px; text-align: left; font-weight: bold; border-right: 1px solid #0f1e35;\">SC\u00c9NARIO<\/th>\n<th style=\"color: #e2e8f0; padding: 10px 10px; text-align: center; font-weight: bold; border-right: 1px solid #0f1e35;\">ACTION DE LA KFDA<\/th>\n<th style=\"color: #e2e8f0; padding: 10px 10px; text-align: center; font-weight: bold; border-right: 1px solid #0f1e35;\">CHRONOLOGIE DE LA R\u00c9VISION<\/th>\n<th style=\"color: #e2e8f0; padding: 10px 10px; text-align: left; font-weight: bold;\">IMPLICATIONS DE LA PLANIFICATION<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #0f1e35;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; font-weight: 600; color: #e2e8f0;\">Qualification initiale \u2014 ZQ80, 20 cav, 10 ml<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #34d399; font-weight: bold;\">soumission du dossier technique du conteneur<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #34d399;\">Pas d'attente pour l'examen de la KFDA<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; color: #94a3b8; font-size: 12px;\">Une marque pharmaceutique cor\u00e9enne valide son CTF interne avant son utilisation commerciale<\/td>\n<\/tr>\n<tr style=\"background: #122338;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; font-weight: 600; color: #e2e8f0;\">Changement de lot de r\u00e9sine \u2014 m\u00eame qualit\u00e9, m\u00eame fournisseur<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #fbbf24; font-weight: bold;\">d\u00e9claration sur l'honneur concernant les changements mineurs<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #fbbf24;\">Imm\u00e9diat<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; color: #94a3b8; font-size: 12px;\">Conserver la documentation du certificat d'analyse\u00a0; v\u00e9rifier que l'indice de min\u00e9ralisation et la densit\u00e9 se situent dans les limites autoris\u00e9es.<\/td>\n<\/tr>\n<tr style=\"background: #0f1e35;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; font-weight: 600; color: #e2e8f0;\">M\u00eame mod\u00e8le ZQ, changement du nombre de cavit\u00e9s (20\u219224)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #f87171; font-weight: bold;\">Avis de changement majeur<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #f87171;\">3 \u00e0 6 mois<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; color: #94a3b8; font-size: 12px;\">Un nouveau rapport dimensionnel cavit\u00e9 par cavit\u00e9 est requis\u00a0; un nouveau test KP complet doit \u00eatre effectu\u00e9 en cas de modifications des parois.<\/td>\n<\/tr>\n<tr style=\"background: #122338;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; font-weight: 600; color: #e2e8f0;\">Mise \u00e0 niveau du mod\u00e8le ZQ (ZQ80\u2192ZQ110)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #f87171; font-weight: bold;\">Avis de changement majeur<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #f87171;\">3 \u00e0 6 mois<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; color: #94a3b8; font-size: 12px;\">Nouveau num\u00e9ro de s\u00e9rie machine dans le CTF\u00a0; r\u00e9p\u00e9ter la qualification dimensionnelle compl\u00e8te au nouveau nombre de cavit\u00e9s<\/td>\n<\/tr>\n<tr style=\"background: #0f1e35;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; font-weight: 600; color: #e2e8f0;\">Changement de qualit\u00e9 de r\u00e9sine (m\u00eame classe de polym\u00e8re)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #f87171; font-weight: bold;\">Avis de changement majeur<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; border-right: 1px solid #1e3a5f; text-align: center; color: #f87171;\">3 \u00e0 6 mois<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #1e3a5f; color: #94a3b8; font-size: 12px;\">Nouveaux tests d'extractibles KP ; nouvelle \u00e9tude de compatibilit\u00e9 avec une nouvelle qualit\u00e9<\/td>\n<\/tr>\n<tr style=\"background: #122338;\">\n<td style=\"padding: 9px 12px; border-right: 1px solid #1e3a5f; font-weight: 600; color: #f59e0b;\">Machine double pr\u00e9qualifi\u00e9e (ZQ80 + ZQ110)<\/td>\n<td style=\"padding: 9px 10px; border-right: 1px solid #1e3a5f; text-align: center; color: #34d399; font-weight: bold;\">Les deux \u00e9taient pr\u00e9-approuv\u00e9s dans la CTF initiale.<\/td>\n<td style=\"padding: 9px 10px; border-right: 1px solid #1e3a5f; text-align: center; color: #34d399;\">Pas d'attente suppl\u00e9mentaire<\/td>\n<td style=\"padding: 9px 10px; color: #94a3b8; font-size: 12px;\">Strat\u00e9gie optimale\u00a0: qualifier les deux machines lors du CTF initial \u2013 cela \u00e9vite une attente ult\u00e9rieure de 3 \u00e0 6 mois lors du passage \u00e0 l\u2019\u00e9chelle.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 0;\">L'implication strat\u00e9gique est claire\u00a0: les fabricants cor\u00e9ens de syst\u00e8mes IBM pharmaceutiques qui pr\u00e9voient une mont\u00e9e en puissance devraient qualifier simultan\u00e9ment la machine initiale et le mod\u00e8le suivant pr\u00e9vu dans le dossier technique du conteneur initial \u2013 moyennant un co\u00fbt documentaire suppl\u00e9mentaire modeste \u2013 afin d'\u00e9liminer le d\u00e9lai d'examen de 3 \u00e0 6\u00a0mois de la KFDA lors de la mont\u00e9e en puissance. <a style=\"color: #1e3a5f; font-weight: 600; text-decoration: none;\" href=\"https:\/\/isbm-blow-molding.com\/fr\/product\/ep-zq80-injection-blow-molding-machine-european-style\/\">Machine IBM EP-ZQ80<\/a> et EP-ZQ110 sont la paire de machines pr\u00e9qualifi\u00e9es la plus couramment dans les projets pharmaceutiques IBM cor\u00e9ens \u2014 la ZQ80 sert de machine de production principale et la ZQ110 de machine secondaire approuv\u00e9e, les deux num\u00e9ros de s\u00e9rie \u00e9tant enregistr\u00e9s dans le CTF initial.<\/p>\n<\/section>\n<p><!-- \u2550\u2550 S3 \u2550\u2550 --><\/p>\n<section id=\"s3\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 03<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">Dossier technique du conteneur \u2014 Documentation requise<\/h2>\n<\/div>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 20px;\">Le dossier technique du conteneur (CTF) est le principal document que l'\u00e9quipe d'assurance qualit\u00e9 d'une marque pharmaceutique cor\u00e9enne exige de son fournisseur de conteneurs IBM avant que le conteneur puisse \u00eatre approuv\u00e9 pour une utilisation en production commerciale. Korea Ever-Power fournit les \u00e9l\u00e9ments de documentation suivants en standard avec chaque commande de machine et de moule IBM pour l'industrie pharmaceutique, r\u00e9duisant ainsi le d\u00e9lai de qualification de la marque pharmaceutique cor\u00e9enne en \u00e9liminant la phase de collecte des donn\u00e9es.<\/p>\n<p><!-- Document checklist - engineering style --><\/p>\n<div style=\"display: flex; flex-direction: column; gap: 2px; margin: 0 0 22px;\">\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-radius: 4px 4px 0 0; overflow: hidden;\">\n<div style=\"background: #1e3a5f; padding: 10px 16px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">DOC 01<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff; letter-spacing: 0.5px;\">SP\u00c9CIFICATIONS ET D\u00c9CLARATION DE CONFORMIT\u00c9 DE LA R\u00c9SINE<\/span><br \/>\n<span style=\"margin-left: auto; background: rgba(52,211,153,0.2); color: #34d399; font-size: 10px; font-weight: bold; padding: 2px 8px; border-radius: 2px;\">COR\u00c9E EVER-POWER FOURNIT<\/span><\/div>\n<div style=\"padding: 14px 18px;\">\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Nom du fabricant de la r\u00e9sine, d\u00e9signation de qualit\u00e9 commerciale PEHD ou PP, num\u00e9ro de lot<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Certificat d'analyse\u00a0: Indice de fusion (g\/10\u00a0min), densit\u00e9 (g\/cm\u00b3), point de fusion, composition des additifs<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>R\u00e9f\u00e9rence \u00e0 la liste positive de la KFDA cor\u00e9enne ou d\u00e9claration de contact pharmaceutique de la KFDA du fournisseur de r\u00e9sine<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Confirmation : sans stabilisateurs UV, sans agents de glissement non r\u00e9pertori\u00e9s, sans colorants interdits<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; overflow: hidden;\">\n<div style=\"background: #1e3a5f; padding: 10px 16px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">DOC 02<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff; letter-spacing: 0.5px;\">DESSIN DIMENSIONNEL DU CONTENEUR<\/span><br \/>\n<span style=\"margin-left: auto; background: rgba(52,211,153,0.2); color: #34d399; font-size: 10px; font-weight: bold; padding: 2px 8px; border-radius: 2px;\">COR\u00c9E EVER-POWER FOURNIT<\/span><\/div>\n<div style=\"padding: 14px 18px;\">\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Toutes les dimensions nominales avec tol\u00e9rances\u00a0: diam\u00e8tre ext\u00e9rieur du col, diam\u00e8tre int\u00e9rieur de l\u2019al\u00e9sage du col, hauteur, diam\u00e8tre ext\u00e9rieur maximal du corps, position du rep\u00e8re de remplissage<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Volume au rep\u00e8re de remplissage : volume nominal \u00b1 tol\u00e9rance \u00e0 23 \u00b0C<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Identification du mat\u00e9riau du contenant\u00a0: PEHD ou PP, couleur, code d\u2019identification de la r\u00e9sine<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Historique des r\u00e9visions et num\u00e9ro de dessin pour le contr\u00f4le des versions dans le dossier KFDA cor\u00e9en<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; overflow: hidden;\">\n<div style=\"background: #1e3a5f; padding: 10px 16px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">DOC 03<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff; letter-spacing: 0.5px;\">IDENTIFICATION DES MACHINES ET DES MOULES<\/span><br \/>\n<span style=\"margin-left: auto; background: rgba(52,211,153,0.2); color: #34d399; font-size: 10px; font-weight: bold; padding: 2px 8px; border-radius: 2px;\">COR\u00c9E EVER-POWER FOURNIT<\/span><\/div>\n<div style=\"padding: 14px 18px;\">\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Mod\u00e8le de machine Korea Ever-Power (par exemple EP-ZQ80) et num\u00e9ro de s\u00e9rie unique de la machine<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Num\u00e9ro de s\u00e9rie du jeu de moules, nombre d'empreintes, mat\u00e9riau du moule (acier inoxydable S136), sch\u00e9ma de num\u00e9rotation des empreintes<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Nom et adresse du site de production (usine du fabricant cor\u00e9en de conteneurs IBM)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>En cas de qualification sur deux machines\u00a0: les deux num\u00e9ros de s\u00e9rie et les deux nombres de cavit\u00e9s doivent \u00eatre document\u00e9s.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; overflow: hidden;\">\n<div style=\"background: #1e3a5f; padding: 10px 16px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">DOC 04<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff; letter-spacing: 0.5px;\">RAPPORT DE QUALIFICATION DIMENSIONNEL CAVIT\u00c9 PAR CAVIT\u00c9<\/span><br \/>\n<span style=\"margin-left: auto; background: rgba(52,211,153,0.2); color: #34d399; font-size: 10px; font-weight: bold; padding: 2px 8px; border-radius: 2px;\">COR\u00c9E EVER-POWER FOURNIT<\/span><\/div>\n<div style=\"padding: 14px 18px;\">\n<p style=\"font-size: 14px; color: #374151; margin: 0 0 10px; line-height: 1.65;\">Korea Ever-Power produit ce rapport lors de l'essai de production pr\u00e9alable \u00e0 la livraison, effectu\u00e9 dans ses installations avant l'exp\u00e9dition de la machine. Ce rapport fournit \u00e0 la marque pharmaceutique cor\u00e9enne les donn\u00e9es dimensionnelles du premier lot avant m\u00eame l'arriv\u00e9e de la machine dans son usine. Ce service exclusif de Korea Ever-Power permet de r\u00e9duire le d\u00e9lai de qualification sur site du client cor\u00e9en gr\u00e2ce \u00e0 des donn\u00e9es dimensionnelles valid\u00e9es issues de la premi\u00e8re production.<\/p>\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>30 mesures par dimension et par cavit\u00e9 (diam\u00e8tre ext\u00e9rieur du col, diam\u00e8tre int\u00e9rieur de l'al\u00e9sage, hauteur, volume, poids de la bouteille)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Toutes les cavit\u00e9s ont \u00e9t\u00e9 mesur\u00e9es sur 3 cycles de production cons\u00e9cutifs (minimum 500 bouteilles).<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>R\u00e9sum\u00e9 statistique\u00a0: moyenne, \u00e9tendue, \u00e9cart type par dimension et par cavit\u00e9\u00a0; confirmation par Cpk \u2265 1,33<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>D\u00e9claration confirmant simultan\u00e9ment la conformit\u00e9 de toutes les cavit\u00e9s aux sp\u00e9cifications \u2014 exig\u00e9e pour le CTF cor\u00e9en KFDA<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-radius: 0 0 4px 4px; overflow: hidden;\">\n<div style=\"background: #1e3a5f; padding: 10px 16px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #475569; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">DOC 05\u201307<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff; letter-spacing: 0.5px;\">TESTS KP \u00b7 COMPATIBILIT\u00c9 \u00b7 FONCTION DE FERMETURE (fournis par un client cor\u00e9en)<\/span><br \/>\n<span style=\"margin-left: auto; background: rgba(100,116,139,0.25); color: #94a3b8; font-size: 10px; font-weight: bold; padding: 2px 8px; border-radius: 2px;\">LE CLIENT S'OCCUPE DE L'ORGANISATION<\/span><\/div>\n<div style=\"padding: 14px 18px;\">\n<p style=\"font-size: 14px; color: #374151; margin: 0; line-height: 1.65;\">Le certificat d'essai des contenants en plastique de la Pharmacop\u00e9e cor\u00e9enne (laboratoire accr\u00e9dit\u00e9 cor\u00e9en), l'\u00e9tude de compatibilit\u00e9 chimique (12 ou 24 semaines \u00e0 40 \u00b0C\/751 TP3T HR avec la formulation pharmaceutique r\u00e9elle) et le test de fermeture (CRC selon KS M ISO 8317, joint d'\u00e9tanch\u00e9it\u00e9 selon ASTM F2096 ou couple d'insertion du bouchon compte-gouttes) sont requis. Ces trois documents sont fournis par la marque pharmaceutique cor\u00e9enne ou son fournisseur de contenants IBM, car ils n\u00e9cessitent l'acc\u00e8s \u00e0 la formulation pharmaceutique et aux composants de fermeture sp\u00e9cifiques \u00e0 la Cor\u00e9e. Les sp\u00e9cifications d\u00e9taill\u00e9es de chaque test sont pr\u00e9sent\u00e9es dans les sections 4, 5 et 6 de ce guide.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550 S4 \u2550\u2550 --><\/p>\n<section id=\"s4\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 04<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">Tests des contenants en plastique de la Pharmacop\u00e9e cor\u00e9enne<\/h2>\n<\/div>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 20px;\">La monographie g\u00e9n\u00e9rale de la Pharmacop\u00e9e cor\u00e9enne (KP) relative aux r\u00e9cipients en plastique \u00e0 usage pharmaceutique sp\u00e9cifie six param\u00e8tres d'essais chimiques pour les r\u00e9cipients pharmaceutiques en PEHD et en PP. Tous les essais doivent \u00eatre r\u00e9alis\u00e9s sur des r\u00e9cipients de production \u2013 et non sur des plaques de m\u00e9lange-ma\u00eetre ou des \u00e9prouvettes moul\u00e9es par injection \u2013 car les conditions du proc\u00e9d\u00e9 IBM (temp\u00e9rature du cylindre, pression d'injection, exposition \u00e0 l'air de soufflage \u00e0 l'int\u00e9rieur du r\u00e9cipient) influent sur le profil d'extractibilit\u00e9 du r\u00e9cipient fini.<\/p>\n<div style=\"overflow-x: auto; margin: 0 0 22px;\">\n<table style=\"width: 100%; border-collapse: collapse; font-size: 13px; min-width: 580px;\">\n<thead>\n<tr style=\"background: #0f1e35;\">\n<th style=\"color: #f59e0b; padding: 11px 12px; text-align: left; font-weight: bold; border-right: 1px solid #1e3a5f;\">PARAM\u00c8TRE DE TEST KP<\/th>\n<th style=\"color: #e2e8f0; padding: 11px 10px; text-align: left; font-weight: bold; border-right: 1px solid #1e3a5f;\">CONDITION D'EXTRACTION<\/th>\n<th style=\"color: #f59e0b; padding: 11px 10px; text-align: center; font-weight: bold; border-right: 1px solid #1e3a5f;\">KP LIMIT<\/th>\n<th style=\"color: #e2e8f0; padding: 11px 10px; text-align: left; font-weight: bold;\">FACTEUR DE RISQUE IBM<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">R\u00e9sidu d'\u00e9vaporation (eau)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\">Eau purifi\u00e9e, 121 \u00b0C, 1 h<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; font-weight: bold; color: #059669;\">\u2264 30 ppm<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Surchauffe du canon (&gt;220 \u00b0C \u00e0 la buse)\u00a0; surveiller les points de consigne de la zone du canon<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">R\u00e9sidu d'\u00e9vaporation (acide ac\u00e9tique 4%)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\">4% CH\u2083COOH, 60 \u00b0C, 30 min<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; font-weight: bold; color: #059669;\">\u2264 30 ppm<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Sensible \u00e0 la migration des antioxydants\u00a0; v\u00e9rifier uniquement la conformit\u00e9 aux normes KFDA AO-1010 ou AO-168<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">R\u00e9sidu d'\u00e9vaporation (n-heptane)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\">n-Heptane, 25 \u00b0C, 1 h<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; font-weight: bold; color: #059669;\">\u2264 30 ppm<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Risque faible pour le PEHD IBM\u00a0; risque accru si un agent de d\u00e9moulage est utilis\u00e9 \u2013 IBM n\u2019utilise pas d\u2019agents de d\u00e9moulage.<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">M\u00e9taux lourds (comme le plomb)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\">Extrait 4% CH\u2083COOH<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; font-weight: bold; color: #059669;\">\u2264 1 ppm<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Faible risque pour le PEHD\/PP\u00a0; risque accru par les stabilisants thermiques \u2014 les qualit\u00e9s pharmaceutiques IBM n\u2019en contiennent aucun<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Ph\u00e9nol<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\">Extrait de chloroforme\/\u00e9thanol<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; font-weight: bold; color: #059669;\">\u2264 5 ppm<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Antioxydants ph\u00e9noliques (AO-1010, BHT) \u2014 maintenir une charge totale en antioxydants \u2264 0,05% dans le PEHD pharmaceutique<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-right: 1px solid #e2e8f0; font-weight: 600;\">consommation de KMnO\u2084<\/td>\n<td style=\"padding: 9px 10px; border-right: 1px solid #e2e8f0;\">Extrait d'eau purifi\u00e9e<\/td>\n<td style=\"padding: 9px 10px; border-right: 1px solid #e2e8f0; text-align: center; font-weight: bold; color: #059669;\">\u2264 10 ppm<\/td>\n<td style=\"padding: 9px 10px; font-size: 12px; color: #475569;\">Augmentation due aux produits de d\u00e9gradation thermique \u2014 indicateur de surchauffe du cylindre IBM\u00a0; fonctionnement aux points de consigne corrects<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-left: 4px solid #d97706; padding: 14px 20px; border-radius: 0 4px 4px 0;\">\n<p style=\"font-size: 13.5px; color: #374151; margin: 0; line-height: 1.7;\"><strong style=\"color: #0f1e35;\">Exigences du laboratoire d'essais\u00a0:<\/strong> Les tests de conditionnement des emballages plastiques KP, n\u00e9cessaires \u00e0 la qualification pharmaceutique par la KFDA cor\u00e9enne, doivent \u00eatre r\u00e9alis\u00e9s par un laboratoire d'essais pharmaceutiques accr\u00e9dit\u00e9 par la KFDA (\ud55c\uad6d\uc758\uc57d\ud488\uc2dc\ud5d8\uc6d0, laboratoire sous contrat enregistr\u00e9 aupr\u00e8s de la KFDA ou laboratoire interne accr\u00e9dit\u00e9 aux BPF cor\u00e9ennes). Les r\u00e9sultats provenant de laboratoires non accr\u00e9dit\u00e9s ne sont pas accept\u00e9s dans le cadre des notifications de changement d'emballage pharmaceutique de la KFDA. Le d\u00e9lai d'obtention des r\u00e9sultats dans les laboratoires accr\u00e9dit\u00e9s cor\u00e9ens est g\u00e9n\u00e9ralement de 3 \u00e0 5 semaines entre le d\u00e9p\u00f4t de l'\u00e9chantillon et la r\u00e9ception du rapport d'essai final. Il est recommand\u00e9 de planifier ces essais en parall\u00e8le des tests de compatibilit\u00e9 (section 5) afin d'\u00e9viter tout retard cons\u00e9cutif et d'allonger le d\u00e9lai global de qualification.<\/p>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550 S5 \u2550\u2550 --><\/p>\n<section id=\"s5\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 05<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">\u00c9tudes de compatibilit\u00e9 et d'extractibles\/relargables<\/h2>\n<\/div>\n<\/div>\n<figure style=\"margin: 0 0 24px;\"><img decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 3px; display: block; border: 1px solid #cbd5e0;\" title=\"Production de conteneurs pharmaceutiques IBM \u2014 Parcours d&#039;\u00e9tude de compatibilit\u00e9\" src=\"https:\/\/isbm-blow-molding.com\/wp-content\/uploads\/2026\/07\/IBM-operating-principle.webp\" alt=\"Proc\u00e9d\u00e9 IBM \u00e0 3 stations pour contenants pharmaceutiques en PEHD\u00a0: injection de pr\u00e9forme \u00e0 la station 1, moulage par soufflage \u00e0 la station 2, d\u00e9moulage \u00e0 la station 3. Le contenant produit n\u00e9cessite une \u00e9tude de compatibilit\u00e9 chimique de la KFDA cor\u00e9enne. \u00c9tude acc\u00e9l\u00e9r\u00e9e de 12 semaines \u00e0 40\u00a0\u00b0C et \u00e0 humidit\u00e9 relative de 75% pour les solutions buvables et de 24 semaines pour les formulations pharmaceutiques ophtalmiques.\" \/><figcaption style=\"font-size: 12px; color: #64748b; margin-top: 8px; padding-left: 10px; border-left: 2px solid #d97706;\">Production IBM \u00e0 3 stations\u00a0\u2014 le conteneur IBM produit \u00e0 la station\u00a03 est celui utilis\u00e9 pour les tests de compatibilit\u00e9 chimique de la KFDA cor\u00e9enne. Ces tests doivent \u00eatre r\u00e9alis\u00e9s avec un conteneur IBM identique \u00e0 celui utilis\u00e9 en production (m\u00eame machine, m\u00eame moule, m\u00eame qualit\u00e9 de PEHD, m\u00eame lot) dans les conditions de production industrielle, et non avec des \u00e9chantillons moul\u00e9s par injection \u00e0 l\u2019\u00e9chelle du laboratoire.<\/figcaption><\/figure>\n<p style=\"font-size: 16px; margin-bottom: 20px;\">L'\u00e9tude de compatibilit\u00e9 chimique est l'\u00e9tape la plus longue du processus de qualification des contenants IBM pharmaceutiques par la KFDA cor\u00e9enne \u2014 et la seule qui ne puisse \u00eatre raccourcie malgr\u00e9 une meilleure pr\u00e9paration, davantage de ressources ou une documentation plus efficace. Sa dur\u00e9e est enti\u00e8rement d\u00e9termin\u00e9e par celle de l'\u00e9tude de stabilit\u00e9 acc\u00e9l\u00e9r\u00e9e sp\u00e9cifi\u00e9e par la KFDA cor\u00e9enne pour la voie d'administration pharmaceutique.<\/p>\n<p><!-- compatibility timeline visual --><\/p>\n<div style=\"background: #0f1e35; border-radius: 4px; padding: 22px 26px; margin: 0 0 22px; border-top: 3px solid #d97706;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 18px;\">QUALIFICATION VOIE CRITIQUE \u00b7 ORALE vs OPHTALMIQUE CONTENEUR IBM<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(min(100%,280px),1fr)); gap: 16px;\">\n<div>\n<p style=\"font-size: 11px; font-weight: bold; color: #94a3b8; margin: 0 0 12px; letter-spacing: 1px; text-transform: uppercase;\">Solution buvable \/ M\u00e9dicament contre le cancer colorectal (12 semaines)<\/p>\n<div style=\"display: flex; flex-direction: column; gap: 4px;\">\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaine 0<\/div>\n<div style=\"flex: 1; background: #1e3a5f; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #e2e8f0;\">Livraison de la machine + premier \u00e9chantillon de production IBM<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 1 \u00e0 3<\/div>\n<div style=\"flex: 1; background: #1e3a5f; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #e2e8f0;\">Tests KP + rapport dimensionnel (parall\u00e8le)<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 0 \u00e0 12<\/div>\n<div style=\"flex: 1; background: #d97706; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #fff; font-weight: bold;\">\u27f6 \u00c9tude de compatibilit\u00e9 40 \u00b0C \/ 75% HR (CHEMIN CRITIQUE)<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 12 \u00e0 14<\/div>\n<div style=\"flex: 1; background: #1e3a5f; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #e2e8f0;\">Test de fonction de fermeture + compilation du rapport<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 14 \u00e0 16<\/div>\n<div style=\"flex: 1; background: #059669; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #fff; font-weight: bold;\">CTF termin\u00e9 \u2192 Approbation QA de la marque pharmaceutique cor\u00e9enne<\/div>\n<\/div>\n<\/div>\n<p style=\"font-size: 11px; color: #64748b; margin: 10px 0 0;\">Total : environ 16 semaines \u00e0 partir du premier \u00e9chantillon de production IBM<\/p>\n<\/div>\n<div>\n<p style=\"font-size: 11px; font-weight: bold; color: #94a3b8; margin: 0 0 12px; letter-spacing: 1px; text-transform: uppercase;\">Ophtalmique (24 semaines \u2014 exigence de la KFDA)<\/p>\n<div style=\"display: flex; flex-direction: column; gap: 4px;\">\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaine 0<\/div>\n<div style=\"flex: 1; background: #1e3a5f; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #e2e8f0;\">Livraison de la machine + premier \u00e9chantillon de production IBM<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 1 \u00e0 3<\/div>\n<div style=\"flex: 1; background: #1e3a5f; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #e2e8f0;\">Tests KP + test de particules + rapport dimensionnel<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 0 \u00e0 24<\/div>\n<div style=\"flex: 1; background: #dc2626; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #fff; font-weight: bold;\">\u27f6 \u00c9tude de compatibilit\u00e9 40 \u00b0C \/ 75% HR (CHEMIN CRITIQUE)<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 24 \u00e0 26<\/div>\n<div style=\"flex: 1; background: #1e3a5f; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #e2e8f0;\">Test de fonctionnement du bouchon compte-gouttes + compilation du rapport<\/div>\n<\/div>\n<div style=\"display: flex; align-items: center; gap: 8px;\">\n<div style=\"width: 80px; flex-shrink: 0; font-size: 11px; color: #64748b; text-align: right;\">Semaines 26 \u00e0 28<\/div>\n<div style=\"flex: 1; background: #059669; border-radius: 2px; padding: 6px 10px; font-size: 12px; color: #fff; font-weight: bold;\">CTF termin\u00e9 \u2192 Approbation QA de la marque pharmaceutique cor\u00e9enne<\/div>\n<\/div>\n<\/div>\n<p style=\"font-size: 11px; color: #64748b; margin: 10px 0 0;\">Total : environ 28 semaines \u00e0 partir du premier \u00e9chantillon de production IBM<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 14px;\">Le protocole d'\u00e9tude de compatibilit\u00e9 de la KFDA cor\u00e9enne exige\u00a0: des flacons IBM remplis de la formulation pharmaceutique commerciale exacte (et non d'un substitut ou d'une solution dilu\u00e9e) au volume de remplissage pr\u00e9vu\u00a0; un stockage \u00e0 40\u00a0\u00b0C \u00b1 2\u00a0\u00b0C \/ 75\u00a0\u00b0THR \u00b1 51\u00a0\u00b0THR (conditions de stabilit\u00e9 acc\u00e9l\u00e9r\u00e9e de la KFDA cor\u00e9enne)\u00a0; un \u00e9chantillonnage au terme de l'\u00e9tude de compatibilit\u00e9 (12 ou 24\u00a0semaines) pour l'analyse des extractibles et le dosage de la formulation. L'analyse des extractibles de l'\u00e9chantillon de stabilit\u00e9 rempli doit confirmer que tous les extractibles du flacon IBM en PEHD ou PP sont inf\u00e9rieurs au seuil de pr\u00e9occupation toxicologique (SPT) de la KFDA cor\u00e9enne pour la voie d'administration pharmaceutique concern\u00e9e\u00a0: voie orale\u00a0: SPT\u00a0: 1,5\u00a0\u00b5g\/jour par compos\u00e9\u00a0; voie ophtalmique\u00a0: SPT\u00a0: 0,15\u00a0\u00b5g\/jour par compos\u00e9 (10\u00a0fois plus strict pour la voie ophtalmique).<\/p>\n<p style=\"font-size: 16px; margin-bottom: 0;\">La production sans bavures d'IBM constitue un avantage direct en mati\u00e8re de r\u00e9duction des risques li\u00e9s aux substances extractibles\u00a0: les op\u00e9rations d'\u00e9bavurage EBM g\u00e9n\u00e8rent des d\u00e9bris de PEHD oxyd\u00e9s qui, s'ils sont pr\u00e9sents dans le contenant au moment du remplissage, augmentent la charge en substances extractibles lors de l'\u00e9tude de compatibilit\u00e9. Les contenants IBM, produits sans aucune op\u00e9ration d'\u00e9bavurage, pr\u00e9sentent un int\u00e9rieur nettement plus propre, comme le d\u00e9montrent les donn\u00e9es relatives aux substances extractibles fournies par un client pharmaceutique cor\u00e9en\u00a0: la consommation de KMnO\u2084 (indicateur de substances extractibles organiques) est syst\u00e9matiquement inf\u00e9rieure \u00e0 celle des contenants EBM fabriqu\u00e9s avec la m\u00eame qualit\u00e9 de r\u00e9sine PEHD et la m\u00eame \u00e9paisseur de paroi. <a style=\"color: #1e3a5f; font-weight: 600; text-decoration: none;\" href=\"https:\/\/isbm-blow-molding.com\/fr\/hdpe-injection-blow-molding\/\">Guide de traitement HDPE IBM<\/a> couvre la temp\u00e9rature du f\u00fbt et les conditions de traitement qui minimisent les produits de d\u00e9gradation thermique contribuant \u00e0 l'augmentation de la consommation de KMnO\u2084 dans les conteneurs pharmaceutiques cor\u00e9ens en PEHD IBM.<\/p>\n<\/section>\n<p><!-- \u2550\u2550 S6 \u2550\u2550 --><\/p>\n<section id=\"s6\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 06<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">Qualification fonctionnelle et dimensionnelle de la fermeture<\/h2>\n<\/div>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 20px;\">La qualification fonctionnelle du syst\u00e8me de fermeture confirme que les contenants IBM, produits selon le nombre d'empreintes et les conditions de production commerciale, s'embo\u00eetent correctement dans leur syst\u00e8me de fermeture pharmaceutique cor\u00e9en d\u00e9sign\u00e9, et ce, sur toute la plage de tol\u00e9rance dimensionnelle du col du contenant IBM et du composant de fermeture cor\u00e9en. L'autorit\u00e9 cor\u00e9enne KFDA exige les donn\u00e9es de qualification fonctionnelle du syst\u00e8me de fermeture dans le dossier technique principal du contenant pour chaque produit pharmaceutique.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(min(100%,270px),1fr)); gap: 14px; margin: 0 0 22px;\">\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-radius: 4px; overflow: hidden;\">\n<div style=\"background: #0f1e35; padding: 11px 16px; display: flex; align-items: center; gap: 8px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 7px; border-radius: 2px;\">CRC<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff;\">Test de fermeture \u00e0 l'\u00e9preuve des enfants<\/span><\/div>\n<div style=\"padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; color: #475569; margin: 0 0 8px; letter-spacing: 1px;\">NORME : KS M ISO 8317<\/p>\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>200 sujets adultes test\u00e9s \u2014 \u2265 85% taux d'ouverture en 5 min (crit\u00e8re d'accessibilit\u00e9 pour adultes)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>200 sujets enfants test\u00e9s \u2014 \u2264 20% taux d'ouverture en 10 min (crit\u00e8re de r\u00e9sistance enfant)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Le diam\u00e8tre ext\u00e9rieur du col IBM est critique \u00e0 \u00b10,05 mm\u00a0; une interf\u00e9rence des billes dans une plage de \u00b10,06 mm est requise.<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Des \u00e9chantillons de conteneurs de qualification ont \u00e9t\u00e9 pr\u00e9lev\u00e9s dans toutes les cavit\u00e9s du moule.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-radius: 4px; overflow: hidden;\">\n<div style=\"background: #0f1e35; padding: 11px 16px; display: flex; align-items: center; gap: 8px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 7px; border-radius: 2px;\">INDUCTION<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff;\">Test d'int\u00e9grit\u00e9 du joint d'\u00e9tanch\u00e9it\u00e9 par induction<\/span><\/div>\n<div style=\"padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; color: #475569; margin: 0 0 8px; letter-spacing: 1px;\">NORME : ASTM F2096<\/p>\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Test de bulles sous pression positive\u00a0: gonfler le r\u00e9cipient scell\u00e9 \u00e0 10\u00a0kPa \u2013 aucune bulle ne doit \u00eatre \u00e9mise au niveau de la zone de scellage.<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Plan\u00e9it\u00e9 de la zone d'\u00e9tanch\u00e9it\u00e9 du col IBM \u2264 0,1 mm TIR requise pour une liaison de feuille uniforme sur toutes les cavit\u00e9s<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Int\u00e9grit\u00e9 de l'\u00e9chantillon 100%\u00a0: tous les contenants de toutes les cavit\u00e9s doivent r\u00e9ussir le lot de qualification<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Simulation post-distribution : r\u00e9p\u00e9ter apr\u00e8s conditionnement ISTA 2A<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-radius: 4px; overflow: hidden;\">\n<div style=\"background: #0f1e35; padding: 11px 16px; display: flex; align-items: center; gap: 8px;\"><span style=\"background: #d97706; color: #fff; font-size: 9px; font-weight: 800; padding: 2px 7px; border-radius: 2px;\">COMPTE-TOUT<\/span><br \/>\n<span style=\"font-size: 12px; font-weight: bold; color: #fff;\">Fonctionnement du bouchon compte-gouttes ophtalmique<\/span><\/div>\n<div style=\"padding: 16px 18px;\">\n<p style=\"font-size: 10px; font-weight: bold; color: #475569; margin: 0 0 8px; letter-spacing: 1px;\">SP\u00c9CIFICATIONS OPHTALMIQUES COR\u00c9ENNES DE LA KFDA<\/p>\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 6px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Volume de goutte : 25 \u00e0 35 \u03bcl par goutte \u00e0 23 \u00b0C, conform\u00e9ment \u00e0 la notice sp\u00e9cifique du compte-gouttes ophtalmique cor\u00e9en.<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Maintien du bouchon compte-gouttes\u00a0: r\u00e9sistance \u00e0 une traction axiale de 10\u00a0N sans d\u00e9tachement du bouchon (test de manipulation r\u00e9alis\u00e9 par des pharmaciens cor\u00e9ens)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Le diam\u00e8tre int\u00e9rieur de l'al\u00e9sage IBM (\u00b10,04 mm) contr\u00f4le le volume des gouttes \u2014 test\u00e9 aux limites nominales et de tol\u00e9rance<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #d97706; font-weight: bold; flex-shrink: 0;\">\u25b8<\/span>Toutes les cavit\u00e9s test\u00e9es\u00a0: 200 conteneurs minimum provenant de chacune des 20 \u00e0 30 cavit\u00e9s de production IBM.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550 S7 \u2550\u2550 --><\/p>\n<section id=\"s7\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 07<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">Processus de notification de changement de la KFDA cor\u00e9enne<\/h2>\n<\/div>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 20px;\">La proc\u00e9dure de notification des modifications d'emballage des produits pharmaceutiques de la KFDA cor\u00e9enne, r\u00e9gie par l'article 32 de la loi cor\u00e9enne sur les affaires pharmaceutiques et la notification des normes de fabrication et de gestion de la qualit\u00e9 des produits pharmaceutiques, classe les modifications du contenant primaire en modifications mineures (autod\u00e9clarables) et modifications majeures (n\u00e9cessitant un examen par la KFDA). Cette classification d\u00e9termine le calendrier que les marques pharmaceutiques cor\u00e9ennes doivent int\u00e9grer \u00e0 leurs plans de projet de modification d'emballage.<\/p>\n<p><!-- change classification cards --><\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(min(100%,280px),1fr)); gap: 14px; margin: 0 0 22px;\">\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-top: 3px solid #059669; border-radius: 4px; padding: 18px 20px;\">\n<div style=\"display: flex; align-items: center; gap: 8px; margin-bottom: 14px;\"><span style=\"background: #059669; color: #fff; font-size: 9px; font-weight: 800; padding: 3px 8px; border-radius: 2px;\">MODIFICATION MINEUR<\/span><br \/>\n<span style=\"font-size: 11px; color: #059669; font-weight: bold;\">Autod\u00e9claration \u00b7 Imm\u00e9diate<\/span><\/div>\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 8px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #059669; font-weight: bold; flex-shrink: 0;\">\u2713<\/span>M\u00eame qualit\u00e9 de PEHD ou de PP, lot de r\u00e9sine diff\u00e9rent (m\u00eame intervalle MI, m\u00eame ensemble d'additifs)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #059669; font-weight: bold; flex-shrink: 0;\">\u2713<\/span>Modification dimensionnelle dans les limites de tol\u00e9rance sp\u00e9cifi\u00e9es (aucune r\u00e9vision du dessin requise)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #059669; font-weight: bold; flex-shrink: 0;\">\u2713<\/span>Changement de couleur au sein de la m\u00eame cat\u00e9gorie opaque\/translucide (colorant de la liste positive de la KFDA)<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #059669; font-weight: bold; flex-shrink: 0;\">\u2713<\/span>Changement de site de production (m\u00eame sp\u00e9cification de conteneur, fabricant IBM cor\u00e9en diff\u00e9rent)<\/li>\n<\/ul>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-top: 3px solid #dc2626; border-radius: 4px; padding: 18px 20px;\">\n<div style=\"display: flex; align-items: center; gap: 8px; margin-bottom: 14px;\"><span style=\"background: #dc2626; color: #fff; font-size: 9px; font-weight: 800; padding: 3px 8px; border-radius: 2px;\">CHANGEMENT MAJEUR<\/span><br \/>\n<span style=\"font-size: 11px; color: #dc2626; font-weight: bold;\">Examen KFDA \u00b7 3 \u00e0 6 mois<\/span><\/div>\n<ul style=\"margin: 0; padding-left: 0; list-style: none; display: flex; flex-direction: column; gap: 8px;\">\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #dc2626; font-weight: bold; flex-shrink: 0;\">\u2717<\/span>Changement de mod\u00e8le de machine IBM (ZQ80 \u2192 ZQ110) \u2014 nouveau num\u00e9ro de s\u00e9rie de la machine dans CTF<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #dc2626; font-weight: bold; flex-shrink: 0;\">\u2717<\/span>Changement du nombre de cavit\u00e9s (20 \u2192 24 cavit\u00e9s) \u2014 nouvelle qualification dimensionnelle requise<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #dc2626; font-weight: bold; flex-shrink: 0;\">\u2717<\/span>Changement de qualit\u00e9 de r\u00e9sine \u2014 nouveaux tests KP et \u00e9tude de compatibilit\u00e9 requis<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #dc2626; font-weight: bold; flex-shrink: 0;\">\u2717<\/span>Changement de type de conteneur (ex. PEHD \u2192 PP pour autoclave) \u2014 requalification compl\u00e8te<\/li>\n<li style=\"font-size: 14px; color: #374151; display: flex; align-items: baseline; gap: 8px;\"><span style=\"color: #dc2626; font-weight: bold; flex-shrink: 0;\">\u2717<\/span>Changement de finition du col (filetage GPI ou diam\u00e8tre diff\u00e9rent) \u2014 requalification du syst\u00e8me de fermeture<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #e2e8f0; border-left: 4px solid #1e3a5f; padding: 16px 20px; border-radius: 0 4px 4px 0; margin: 0 0 16px;\">\n<p style=\"font-size: 13.5px; color: #374151; margin: 0; line-height: 1.7;\"><strong style=\"color: #0f1e35;\">Qualification des deux machines \u2014 la strat\u00e9gie de planification essentielle\u00a0:<\/strong> Les fabricants cor\u00e9ens de syst\u00e8mes IBM pour l'industrie pharmaceutique qui qualifient simultan\u00e9ment deux mod\u00e8les ZQ (par exemple, ZQ80, num\u00e9ro de s\u00e9rie #001, et ZQ110, num\u00e9ro de s\u00e9rie #002) dans le dossier technique initial du conteneur supportent un co\u00fbt documentaire suppl\u00e9mentaire modeste (rapport dimensionnel et documentation d'installation de la seconde machine), mais s'affranchissent totalement de l'examen de modification majeure de la KFDA, d'une dur\u00e9e de 3 \u00e0 6 mois, lors de la mise en service du ZQ110 pour la production \u00e0 grande \u00e9chelle. Les \u00e9conomies r\u00e9alis\u00e9es gr\u00e2ce \u00e0 l'\u00e9vitement d'un examen de notification de modification majeure \u2013 en termes de co\u00fbts li\u00e9s aux retards de production, aux ressources r\u00e9glementaires et aux opportunit\u00e9s pour la marque pharmaceutique cor\u00e9enne \u2013 d\u00e9passent syst\u00e9matiquement de 10 \u00e0 20 fois le co\u00fbt de la documentation de qualification des deux machines. Korea Ever-Power recommande la qualification des deux machines comme pratique standard pour tous les projets IBM cor\u00e9ens pour l'industrie pharmaceutique, lorsqu'une augmentation de la capacit\u00e9 au-del\u00e0 de la capacit\u00e9 annuelle initiale de la machine est pr\u00e9vue dans les 5 ans suivant le lancement du projet.<\/p>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550 S8 \u2550\u2550 --><\/p>\n<section id=\"s8\" style=\"margin: 56px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 22px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #fff; border: 1px solid #e2e8f0; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">SECTION 08<\/p>\n<h2 style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #0f1e35; margin: 0; line-height: 1.2;\">Ensemble de documentation d'assistance GMP Ever-Power Cor\u00e9e<\/h2>\n<\/div>\n<\/div>\n<figure style=\"margin: 0 0 24px;\"><img decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 3px; display: block; border: 1px solid #cbd5e0;\" title=\"Atelier Korea Ever-Power \u2014 Assistance \u00e0 la documentation BPF pharmaceutique\" src=\"https:\/\/isbm-blow-molding.com\/wp-content\/uploads\/2026\/07\/ever-power-workshop-1.webp\" alt=\"Atelier de fabrication de machines IBM Ever-Power en Cor\u00e9e \u2014 Essai de production avant livraison d&#039;une machine IBM pharmaceutique, produisant des donn\u00e9es de qualification dimensionnelle cavit\u00e9 par cavit\u00e9 incluses dans le dossier technique des contenants pharmaceutiques de la KFDA cor\u00e9enne (documentation BPF).\" \/><figcaption style=\"font-size: 12px; color: #64748b; margin-top: 8px; padding-left: 10px; border-left: 2px solid #d97706;\">L'usine de Korea Ever-Power, sp\u00e9cialis\u00e9e dans la fabrication de machines IBM pour l'industrie pharmaceutique, effectue des essais de production avant livraison avec le moule du client. Ces essais permettent d'obtenir les donn\u00e9es dimensionnelles d\u00e9taill\u00e9es, cavit\u00e9 par cavit\u00e9, qui constituent la base du dossier technique de qualification des contenants pharmaceutiques aupr\u00e8s de la KFDA cor\u00e9enne. Ce service de qualification avant livraison r\u00e9duit le d\u00e9lai de qualification sur site du client cor\u00e9en en fournissant des donn\u00e9es dimensionnelles de production valid\u00e9es avant m\u00eame l'arriv\u00e9e de la machine \u00e0 l'usine.<\/figcaption><\/figure>\n<p style=\"font-size: 16px; margin-bottom: 20px;\">Korea Ever-Power fournit un ensemble de documentation BPF standardis\u00e9 avec chaque machine IBM pharmaceutique et chaque moule livr\u00e9. Cet ensemble comprend les \u00e9l\u00e9ments de documentation que Korea Ever-Power peut produire dans son usine. Les \u00e9l\u00e9ments n\u00e9cessitant les donn\u00e9es de formulation de la marque pharmaceutique cor\u00e9enne et du fournisseur cor\u00e9en de bouchons sont identifi\u00e9s s\u00e9par\u00e9ment comme \u00e9l\u00e9ments fournis par le client dans le cadre du CTF.<\/p>\n<p><!-- documentation package summary table --><\/p>\n<div style=\"overflow-x: auto; margin: 0 0 22px;\">\n<table style=\"width: 100%; border-collapse: collapse; font-size: 13px; min-width: 560px;\">\n<thead>\n<tr style=\"background: #0f1e35;\">\n<th style=\"color: #f59e0b; padding: 11px 12px; text-align: left; font-weight: bold; border-right: 1px solid #1e3a5f;\">DOCUMENTATION<\/th>\n<th style=\"color: #e2e8f0; padding: 11px 10px; text-align: center; font-weight: bold; border-right: 1px solid #1e3a5f;\">FOURNI PAR<\/th>\n<th style=\"color: #e2e8f0; padding: 11px 10px; text-align: center; font-weight: bold; border-right: 1px solid #1e3a5f;\">D\u00c9LAIS DE LIVRAISON<\/th>\n<th style=\"color: #e2e8f0; padding: 11px 10px; text-align: left; font-weight: bold;\">NOTES<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Certificat d'identification de la machine (num\u00e9ro de s\u00e9rie, mod\u00e8le, sp\u00e9cifications)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #059669; font-weight: bold;\">KEP<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Livraison par machine<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Inclut les certificats pour deux machines si pr\u00e9qualifi\u00e9.<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Sp\u00e9cifications techniques du moule (nombre de cavit\u00e9s, mat\u00e9riau, disposition)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #059669; font-weight: bold;\">KEP<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Livraison du moule<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Certificat d'authenticit\u00e9 du mat\u00e9riau de la cavit\u00e9 en acier inoxydable S136 inclus<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Rapport dimensionnel cavit\u00e9 par cavit\u00e9 avant livraison (500 bouteilles)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #059669; font-weight: bold;\">KEP<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Avant l'exp\u00e9dition<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569; font-weight: 600;\">Service KEP unique \u2014 r\u00e9duit le d\u00e9lai de qualification sur site des clients cor\u00e9ens<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Dessin dimensionnel du conteneur (toutes les dimensions, tol\u00e9rances)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #059669; font-weight: bold;\">KEP<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Approbation du moule<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Num\u00e9ro de document contr\u00f4l\u00e9 pour la gestion des versions du KFDA CTF cor\u00e9en<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Enregistrement des param\u00e8tres de processus IBM (conditions de production standard)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #059669; font-weight: bold;\">KEP<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Avec essai avant livraison<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Temp\u00e9ratures du cylindre, pression d'injection, pression de soufflage, temps de cycle\u00a0: constituent la base de r\u00e9f\u00e9rence du processus ma\u00eetre conforme aux BPF cor\u00e9ennes.<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">Test des contenants en plastique de la Pharmacop\u00e9e cor\u00e9enne (substances extractibles KP)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #d97706; font-weight: bold;\">Client (laboratoire cor\u00e9en)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Semaines 1 \u00e0 4<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Laboratoire cor\u00e9en accr\u00e9dit\u00e9 par la KFDA\u00a0; KEP fournit des conteneurs IBM d\u2019\u00e9chantillons<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; font-weight: 600;\">\u00c9tude de compatibilit\u00e9 chimique (stabilit\u00e9 \u00e0 l'\u00e9tat rempli, 12 ou 24 semaines)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center; color: #d97706; font-weight: bold;\">Client (marque pharmaceutique cor\u00e9enne)<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0; text-align: center;\">Semaines 0 \u00e0 12 \/ 0 \u00e0 24<\/td>\n<td style=\"padding: 9px 10px; border-bottom: 1px solid #e2e8f0; font-size: 12px; color: #475569;\">Chemin critique\u00a0\u2014 commencer imm\u00e9diatement apr\u00e8s r\u00e9ception des premiers \u00e9chantillons de production IBM<\/td>\n<\/tr>\n<tr style=\"background: #f8fafc;\">\n<td style=\"padding: 9px 12px; border-right: 1px solid #e2e8f0; font-weight: 600;\">Test de fonctionnement du syst\u00e8me de fermeture (CRC \/ joint \u00e0 induction \/ bouchon compte-gouttes)<\/td>\n<td style=\"padding: 9px 10px; border-right: 1px solid #e2e8f0; text-align: center; color: #d97706; font-weight: bold;\">Client (marque pharmaceutique cor\u00e9enne)<\/td>\n<td style=\"padding: 9px 10px; border-right: 1px solid #e2e8f0; text-align: center;\">Semaines 12 \u00e0 14<\/td>\n<td style=\"padding: 9px 10px; font-size: 12px; color: #475569;\">Le rapport de pr\u00e9-livraison KEP fournit une base dimensionnelle de r\u00e9f\u00e9rence pour la v\u00e9rification de l'engagement de fermeture<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: 16px; margin-bottom: 0;\">Le pack d'essais de production et de documentation avant livraison de Korea Ever-Power r\u00e9duit le d\u00e9lai de qualification sur site des clients cor\u00e9ens du secteur pharmaceutique (IBM) de 24 \u00e0 28 semaines (de la livraison de la machine \u00e0 la validation finale) \u00e0 environ 16 \u00e0 20 semaines pour les contenants oraux et 26 \u00e0 28 semaines pour les contenants ophtalmiques. Le d\u00e9lai restant est enti\u00e8rement d\u00e9termin\u00e9 par la dur\u00e9e de l'\u00e9tude de compatibilit\u00e9, qui ne peut \u00eatre raccourcie, quelle que soit l'efficacit\u00e9 de la documentation. Les projets IBM pharmaceutiques cor\u00e9ens int\u00e9grant le pack de documentation BPF de Korea Ever-Power d\u00e8s la phase de planification obtiennent syst\u00e9matiquement l'approbation AQ des marques pharmaceutiques cor\u00e9ennes dans les meilleurs d\u00e9lais pour chaque voie d'administration. Pour toute question concernant le pack de documentation BPF, veuillez contacter l'\u00e9quipe d'application pharmaceutique de Korea Ever-Power, qui fournit un calendrier de projet et une liste de contr\u00f4le de validation finale lors de la consultation pr\u00e9alable \u00e0 la commande. Le guide IBM pharmaceutique d\u00e9taille les exigences de qualification sp\u00e9cifiques aux mat\u00e9riaux pour les contenants en PEHD et en PP.<\/p>\n<\/section>\n<p><!-- \u2550\u2550 FAQ \u2550\u2550 --><\/p>\n<section style=\"margin: 64px 0 0;\">\n<div style=\"display: flex; align-items: stretch; gap: 0; margin-bottom: 24px;\">\n<div style=\"width: 4px; background: linear-gradient(180deg,#d97706,#f59e0b); border-radius: 2px; flex-shrink: 0;\"><\/div>\n<div style=\"padding: 10px 16px; background: #0f1e35; border-left: none; flex: 1;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 3px;\">FAQ R\u00c9GLEMENTAIRE<\/p>\n<h2 id=\"faq\" style=\"font-size: clamp(17px,2.4vw,22px); font-weight: 800; color: #fff; margin: 0; line-height: 1.2;\">Questions d'ing\u00e9nierie r\u00e9glementaire sur les BPF de la KFDA cor\u00e9enne<\/h2>\n<\/div>\n<\/div>\n<div style=\"display: flex; flex-direction: column; gap: 2px;\">\n<div style=\"border: 1px solid #e2e8f0; border-radius: 4px 4px 0 0; overflow: hidden; margin-bottom: 2px;\">\n<div style=\"background: #1e3a5f; padding: 13px 18px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 10px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">Q 01<\/span><\/p>\n<p style=\"font-size: 14px; font-weight: bold; color: #fff; margin: 0; line-height: 1.3;\">Quelle est la premi\u00e8re action qu'une marque pharmaceutique cor\u00e9enne doit entreprendre lorsqu'elle planifie une nouvelle qualification de conteneur IBM\u00a0?<\/p>\n<\/div>\n<div style=\"padding: 18px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">La premi\u00e8re \u00e9tape consiste \u00e0 \u00e9tablir le chemin critique du projet de qualification en identifiant la voie d'administration, car celle-ci d\u00e9termine la dur\u00e9e de l'\u00e9tude de compatibilit\u00e9, qui r\u00e9git l'ensemble du calendrier de qualification. Les contenants IBM pour m\u00e9dicaments oraux n\u00e9cessitent 12 semaines de tests de compatibilit\u00e9 acc\u00e9l\u00e9r\u00e9s\u00a0; les contenants ophtalmiques, 24 semaines. Le plan du projet de qualification doit \u00eatre \u00e9labor\u00e9 \u00e0 rebours \u00e0 partir de la date de production commerciale requise, la date de d\u00e9but de l'\u00e9tude de compatibilit\u00e9 servant de point d'ancrage. L'\u00e9tude de compatibilit\u00e9 doit d\u00e9buter le jour de la r\u00e9ception des premiers \u00e9chantillons de production IBM du fabricant de contenants IBM, et non apr\u00e8s la r\u00e9alisation des autres activit\u00e9s de documentation. Toutes les autres activit\u00e9s de qualification (tests KP, rapport dimensionnel, test de fermeture, compilation du CTF) doivent \u00eatre planifi\u00e9es de mani\u00e8re \u00e0 \u00eatre r\u00e9alis\u00e9es pendant la p\u00e9riode de l'\u00e9tude de compatibilit\u00e9, afin que le CTF soit complet lorsque les r\u00e9sultats de l'\u00e9tude de compatibilit\u00e9 sont disponibles. Les marques pharmaceutiques cor\u00e9ennes qui d\u00e9butent l'\u00e9tude de compatibilit\u00e9 apr\u00e8s avoir termin\u00e9 les autres activit\u00e9s ajoutent inutilement 3 \u00e0 6 semaines au calendrier de qualification. L'\u00e9quipe d'application pharmaceutique de Korea Ever-Power fournit un mod\u00e8le de calendrier de projet de qualification au format Gantt \u00e0 tous les clients pharmaceutiques cor\u00e9ens d'IBM lors de la phase de consultation pr\u00e9alable \u00e0 la commande, avec l'\u00e9tude de compatibilit\u00e9 comme point d'ancrage du chemin critique fixe et toutes les autres activit\u00e9s pr\u00e9sent\u00e9es comme des flux de travail parall\u00e8les.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #e2e8f0; overflow: hidden; margin-bottom: 2px;\">\n<div style=\"background: #1e3a5f; padding: 13px 18px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 10px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">Q 02<\/span><\/p>\n<p style=\"font-size: 14px; font-weight: bold; color: #fff; margin: 0; line-height: 1.3;\">Quelle documentation KFDA cor\u00e9enne est requise lorsque le fournisseur de r\u00e9sine HDPE modifie la composition des additifs au sein d'une m\u00eame d\u00e9signation de qualit\u00e9\u00a0?<\/p>\n<\/div>\n<div style=\"padding: 18px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">La modification apport\u00e9e par un fournisseur de r\u00e9sine \u00e0 la composition des additifs d'une m\u00eame qualit\u00e9 commerciale de PEHD (m\u00eame si le nom de la qualit\u00e9 et la sp\u00e9cification MI restent inchang\u00e9s) constitue une modification de substance au sens de la KFDA cor\u00e9enne, car les additifs font partie de la composition de la r\u00e9sine d\u00e9clar\u00e9e dans le dossier technique du contenant d'origine. Le traitement appropri\u00e9 par la KFDA cor\u00e9enne d\u00e9pend de la nature de la modification\u00a0: si celle-ci se limite \u00e0 une variation d'un lot \u00e0 l'autre du m\u00eame type et de la m\u00eame charge d'antioxydant (\u00e0 \u00b1101\u00a0TP3T de la quantit\u00e9 d'antioxydant d\u00e9clar\u00e9e) et que le fournisseur de r\u00e9sine fournit un certificat d'analyse r\u00e9vis\u00e9 le confirmant, l'\u00e9quipe d'assurance qualit\u00e9 de la marque pharmaceutique cor\u00e9enne peut d\u00e9clarer elle-m\u00eame la modification comme mineure. Si le type d'additif change (par exemple, si l'AO-1010 est remplac\u00e9 par un autre antioxydant), si un nouvel antioxydant est ajout\u00e9 ou si la charge en AO varie de plus de \u00b110% par rapport \u00e0 la quantit\u00e9 d\u00e9clar\u00e9e, il s'agit d'une modification majeure n\u00e9cessitant une notification \u00e0 la KFDA cor\u00e9enne et, g\u00e9n\u00e9ralement, la r\u00e9alisation d'un nouveau test d'extractibles selon la Pharmacop\u00e9e cor\u00e9enne, voire d'une nouvelle \u00e9tude de compatibilit\u00e9 chimique si la modification de l'additif est susceptible d'affecter le profil d'extractibles au contact de la formulation pharmaceutique. Les fabricants cor\u00e9ens d'IBM pharmaceutiques doivent exiger de leur fournisseur de r\u00e9sine PEHD une notification \u00e9crite officielle de toute modification de l'emballage des additifs au moins 90 jours avant sa mise en \u0153uvre. Ce d\u00e9lai est suffisant pour permettre \u00e0 l'\u00e9quipe d'assurance qualit\u00e9 de la marque pharmaceutique cor\u00e9enne d'\u00e9valuer la classification de la modification par la KFDA et d'engager les actions r\u00e9glementaires appropri\u00e9es avant la mise en production du nouveau lot de r\u00e9sine.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #e2e8f0; overflow: hidden; margin-bottom: 2px;\">\n<div style=\"background: #1e3a5f; padding: 13px 18px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 10px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">Q 03<\/span><\/p>\n<p style=\"font-size: 14px; font-weight: bold; color: #fff; margin: 0; line-height: 1.3;\">La qualification des contenants pharmaceutiques par la KFDA cor\u00e9enne peut-elle \u00eatre effectu\u00e9e en dehors de la Cor\u00e9e, par exemple dans les installations de Korea Ever-Power en Cor\u00e9e\u00a0?<\/p>\n<\/div>\n<div style=\"padding: 18px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">Le dossier technique de qualification des contenants pharmaceutiques par la KFDA cor\u00e9enne peut \u00eatre constitu\u00e9 \u00e0 partir de donn\u00e9es provenant de plusieurs sites\u00a0: les donn\u00e9es dimensionnelles de Korea Ever-Power sont produites dans son usine d\u2019Ansan-si, en Cor\u00e9e\u00a0; les analyses chimiques conformes \u00e0 la Pharmacop\u00e9e cor\u00e9enne sont r\u00e9alis\u00e9es dans un laboratoire accr\u00e9dit\u00e9 par la KFDA (situ\u00e9 en Cor\u00e9e ou \u00e0 l\u2019\u00e9tranger s\u2019il poss\u00e8de l\u2019accr\u00e9ditation KFDA ou ICH requise)\u00a0; et l\u2019\u00e9tude de compatibilit\u00e9 est men\u00e9e par le fabricant du m\u00e9dicament cor\u00e9en dans son installation de stockage de stabilit\u00e9 conforme aux BPF cor\u00e9ennes ou par un organisme de recherche sous contrat cor\u00e9en qualifi\u00e9. Il est imp\u00e9ratif que tous les tests soient effectu\u00e9s avec des contenants IBM produits sur la machine IBM qualifi\u00e9e, sur le site de production qualifi\u00e9. Ce site de production doit \u00eatre identifi\u00e9 dans le dossier technique du contenant, et la qualification KFDA est sp\u00e9cifique \u00e0 ce site. Cela signifie qu'une marque pharmaceutique cor\u00e9enne souhaitant qualifier un emballage IBM provenant d'un fabricant cor\u00e9en d'emballages IBM (\u00e0 l'aide d'une machine Korea Ever-Power ZQ dans l'usine du fabricant cor\u00e9en) doit produire les emballages de qualification dans l'usine dudit fabricant IBM cor\u00e9en, et non dans l'usine Korea Ever-Power d'Ansan-si, sauf si Korea Ever-Power figure sur la liste des fournisseurs qualifi\u00e9s de la marque pharmaceutique cor\u00e9enne en tant que fabricant principal d'emballages. Le r\u00f4le de Korea Ever-Power dans le processus de qualification est celui de fournisseur de machines (fourniture de la machine, du moule et de la documentation dimensionnelle avant livraison), et non celui de fabricant principal d'emballages, sauf si une marque pharmaceutique cor\u00e9enne sp\u00e9cifique fait appel directement \u00e0 Korea Ever-Power en tant que fournisseur principal d'emballages dans le cadre d'un accord de fournisseur qualifi\u00e9 distinct.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #e2e8f0; overflow: hidden; margin-bottom: 2px;\">\n<div style=\"background: #1e3a5f; padding: 13px 18px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 10px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">Q 04<\/span><\/p>\n<p style=\"font-size: 14px; font-weight: bold; color: #fff; margin: 0; line-height: 1.3;\">Comment l'autorit\u00e9 cor\u00e9enne KFDA traite-t-elle la qualification des contenants IBM pour les produits pharmaceutiques g\u00e9n\u00e9riques entrant sur le march\u00e9 cor\u00e9en\u00a0?<\/p>\n<\/div>\n<div style=\"padding: 18px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">L'enregistrement des m\u00e9dicaments g\u00e9n\u00e9riques aupr\u00e8s de la KFDA cor\u00e9enne (\uc81c\ub124\ub9ad \uc758\uc57d\ud488 \ud488\ubaa9\ud5c8\uac00) exige la qualification du contenant primaire dans le cadre du dossier de soumission complet. Pour les m\u00e9dicaments g\u00e9n\u00e9riques destin\u00e9s au march\u00e9 cor\u00e9en, lorsqu'un m\u00e9dicament de r\u00e9f\u00e9rence \u00e9quivalent est d\u00e9j\u00e0 enregistr\u00e9 avec un contenant primaire sp\u00e9cifique (par exemple, un produit ophtalmique utilisant un flacon IBM en PEHD de 10 ml), le demandeur doit soumettre des donn\u00e9es de qualification du contenant primaire d\u00e9montrant sa bio\u00e9quivalence\u00a0: m\u00eame type de contenant (IBM en PEHD, 10 ml), m\u00eame syst\u00e8me de fermeture (m\u00eame bouchon compte-gouttes \u00e0 filetage GPI) et donn\u00e9es relatives aux substances extractibles\/relargables confirmant l'absence de compos\u00e9s extractibles nouveaux ou en concentration accrue par rapport au contenant du m\u00e9dicament de r\u00e9f\u00e9rence. En pratique, les demandeurs cor\u00e9ens de m\u00e9dicaments g\u00e9n\u00e9riques n'ont pas besoin de reproduire l'int\u00e9gralit\u00e9 de la qualification du contenant du m\u00e9dicament de r\u00e9f\u00e9rence\u00a0; ils doivent d\u00e9montrer que leur contenant IBM respecte les m\u00eames normes de la KFDA cor\u00e9enne que le contenant du m\u00e9dicament de r\u00e9f\u00e9rence, en utilisant un fabricant cor\u00e9en de contenants IBM qualifi\u00e9 et en fournissant un dossier complet de qualification du contenant (CTF). Le dossier de pr\u00e9-livraison de Korea Ever-Power est aussi efficace pour les demandeurs d'autorisation de mise sur le march\u00e9 de m\u00e9dicaments g\u00e9n\u00e9riques cor\u00e9ens que pour les m\u00e9dicaments de marque innovants\u00a0: le rapport dimensionnel d\u00e9taill\u00e9, la certification de la machine et le sch\u00e9ma du contenant sont tout aussi utiles pour la soumission d'un dossier de m\u00e9dicament g\u00e9n\u00e9rique \u00e0 la KFDA cor\u00e9enne que pour une demande d'autorisation de mise sur le march\u00e9 d'un m\u00e9dicament de marque innovant. Les projets de m\u00e9dicaments g\u00e9n\u00e9riques cor\u00e9ens utilisant les contenants IBM de Korea Ever-Power et le dossier de documentation BPF standard ont un d\u00e9lai de pr\u00e9paration typique de 8 \u00e0 14 semaines pour la KFDA, depuis le premier \u00e9chantillon de production IBM jusqu'\u00e0 la finalisation de la section emballage du dossier pharmaceutique, lorsque l'\u00e9tude de compatibilit\u00e9 est la seule \u00e9tape critique.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #e2e8f0; overflow: hidden; margin-bottom: 2px;\">\n<div style=\"background: #1e3a5f; padding: 13px 18px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 10px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">Q 05<\/span><\/p>\n<p style=\"font-size: 14px; font-weight: bold; color: #fff; margin: 0; line-height: 1.3;\">Quelle est la proc\u00e9dure correcte de la KFDA cor\u00e9enne si une cavit\u00e9 d'un moule IBM \u00e0 24 cavit\u00e9s pr\u00e9sente des dimensions hors sp\u00e9cifications\u00a0?<\/p>\n<\/div>\n<div style=\"padding: 18px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">Si l'une des 24 cavit\u00e9s d'un moule IBM pr\u00e9sente des dimensions hors sp\u00e9cifications dans le rapport dimensionnel de qualification, la qualification ne peut se poursuivre tant que cette cavit\u00e9 n'est pas conforme. En effet, la qualification des contenants pharmaceutiques par la KFDA cor\u00e9enne exige que toutes les cavit\u00e9s soient simultan\u00e9ment conformes, et non un \u00e9chantillon statistique. La proc\u00e9dure correcte est la suivante\u00a0: (1) Identifier la cavit\u00e9 hors sp\u00e9cifications par son num\u00e9ro dans le rapport dimensionnel. (2) D\u00e9terminer la cause premi\u00e8re\u00a0: d\u00e9s\u00e9quilibre de la buse d'injection (cas le plus fr\u00e9quent\u00a0: une cavit\u00e9 pr\u00e9sente un poids insuffisant et un diam\u00e8tre ext\u00e9rieur du col trop faible), erreur dimensionnelle de l'insert (n\u00e9cessitant un r\u00e9usinage ou un remplacement), ou usure du noyau au niveau de la cavit\u00e9 hors sp\u00e9cifications (n\u00e9cessitant une inspection et un remplacement du noyau si son diam\u00e8tre ext\u00e9rieur est inf\u00e9rieur \u00e0 la valeur nominale). (3) Mettre en \u0153uvre l'action corrective sur la cavit\u00e9 concern\u00e9e\u00a0: r\u00e9glage de l'insert de la buse d'injection (en cas de d\u00e9s\u00e9quilibre d'\u00e9coulement), remplacement de l'insert (en cas d'erreur dimensionnelle) ou remplacement du noyau (en cas d'usure). (4) R\u00e9p\u00e9tez le contr\u00f4le dimensionnel cavit\u00e9 par cavit\u00e9 \u2013 500 cycles de production cons\u00e9cutifs sur l'ensemble des 24 cavit\u00e9s \u2013 afin de confirmer que les 24 cavit\u00e9s sont simultan\u00e9ment conformes aux sp\u00e9cifications. (5) Soumettez le rapport dimensionnel corrig\u00e9 comme rapport de qualification. L'\u00e9quipe AQ \u200b\u200bde la marque pharmaceutique cor\u00e9enne doit \u00eatre inform\u00e9e de toute cavit\u00e9 non conforme et des mesures correctives prises\u00a0; cette information fait partie de la documentation relative \u00e0 la gestion des \u00e9carts de qualification dans le syst\u00e8me qualit\u00e9 BPF cor\u00e9en. L'\u00e9quipe d'ing\u00e9nierie des moules de Korea Ever-Power fournit une analyse des causes profondes et un accompagnement pour les mesures correctives en cas de cavit\u00e9 non conforme, dans le cadre d'un service apr\u00e8s-vente inclus dans la garantie standard des moules pharmaceutiques IBM.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #e2e8f0; border-radius: 0 0 4px 4px; overflow: hidden; margin-bottom: 64px;\">\n<div style=\"background: #1e3a5f; padding: 13px 18px; display: flex; align-items: center; gap: 10px;\"><span style=\"background: #d97706; color: #fff; font-size: 10px; font-weight: 800; padding: 2px 8px; border-radius: 2px; flex-shrink: 0;\">Q 06<\/span><\/p>\n<p style=\"font-size: 14px; font-weight: bold; color: #fff; margin: 0; line-height: 1.3;\">La norme cor\u00e9enne KFDA relative aux conteneurs pharmaceutiques GMP exige-t-elle une requalification annuelle ou une revalidation p\u00e9riodique des conteneurs IBM\u00a0?<\/p>\n<\/div>\n<div style=\"padding: 18px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">Les BPF (Bonnes Pratiques de Fabrication) des contenants pharmaceutiques cor\u00e9ens (KFDA) n'exigent pas de requalification p\u00e9riodique des contenants IBM produits sans modification. La qualification initiale reste valide tant qu'aucune modification n'est apport\u00e9e \u00e0 l'\u00e9quipement de production (machine, moule), au mat\u00e9riau (qualit\u00e9 de r\u00e9sine, lot conforme aux sp\u00e9cifications) ou aux conditions de fabrication (au-del\u00e0 des variations normales des param\u00e8tres de fabrication dans les limites de contr\u00f4le). Cependant, les fabricants pharmaceutiques cor\u00e9ens respectant les BPF sont tenus de contr\u00f4ler la qualit\u00e9 des contenants de mani\u00e8re continue via leur syst\u00e8me qualit\u00e9\u00a0: contr\u00f4le du poids des contenants cavit\u00e9 par cavit\u00e9 (indicateur de la constance de l'\u00e9paisseur de paroi, g\u00e9n\u00e9ralement effectu\u00e9 au d\u00e9but, au milieu et \u00e0 la fin de chaque lot de production cor\u00e9en), mesure p\u00e9riodique du diam\u00e8tre ext\u00e9rieur du col (la fr\u00e9quence \u00e9tant d\u00e9termin\u00e9e par les donn\u00e9es de capabilit\u00e9 du proc\u00e9d\u00e9 de la marque pharmaceutique \u2013 g\u00e9n\u00e9ralement tous les 500\u00a0000 cycles pour les moules pharmaceutiques IBM) et analyse annuelle des substances extractibles (optionnelle, mais de plus en plus attendue par les \u00e9quipes d'assurance qualit\u00e9 des marques pharmaceutiques cor\u00e9ennes suite \u00e0 la mise \u00e0 jour des directives d'inspection BPF de la MFDS cor\u00e9enne en 2024). Lorsque le jeu de moules IBM approche de l'intervalle de repolissage recommand\u00e9 par Korea Ever-Power (500\u00a0000 cycles pour les moules pharmaceutiques) ou de l'intervalle de remplacement des noyaux (g\u00e9n\u00e9ralement 2 \u00e0 3 millions de cycles pour les moules IBM en PEHD pharmaceutiques), le fabricant de moules IBM pharmaceutiques doit en informer l'\u00e9quipe AQ \u200b\u200bde la marque pharmaceutique cor\u00e9enne. Les donn\u00e9es de contr\u00f4le dimensionnel de la p\u00e9riode pr\u00e9c\u00e9dant l'intervalle de maintenance doivent d\u00e9montrer que le contenant reste conforme aux sp\u00e9cifications de qualification pendant toute la p\u00e9riode de production pr\u00e9c\u00e9dant la maintenance. Apr\u00e8s la maintenance, une v\u00e9rification dimensionnelle du premier article doit confirmer que les dimensions sont de nouveau conformes aux sp\u00e9cifications avant la reprise de la production commerciale. Cette documentation de maintenance est int\u00e9gr\u00e9e au registre de contr\u00f4le des modifications du fabricant pharmaceutique cor\u00e9en BPF. Il ne s'agit pas d'une notification r\u00e9glementaire \u00e0 la KFDA cor\u00e9enne, mais d'un document du syst\u00e8me qualit\u00e9 interne que les inspecteurs BPF du MFDS cor\u00e9en peuvent consulter lors des inspections des installations BPF cor\u00e9ennes.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- CTA --><\/p>\n<div style=\"margin: 0 0 72px; background: #0f1e35; border-radius: 4px; overflow: hidden; position: relative;\">\n<div style=\"height: 4px; background: linear-gradient(90deg,#d97706,#f59e0b,#d97706);\"><\/div>\n<div style=\"position: absolute; right: 0; top: 0; bottom: 0; width: 40%; background: linear-gradient(135deg,transparent 0%,rgba(30,58,95,0.5) 100%); pointer-events: none;\"><\/div>\n<div style=\"position: relative; padding: clamp(32px,5vw,52px) clamp(24px,4vw,48px); text-align: center;\">\n<p style=\"font-size: 9px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #d97706; margin: 0 0 14px;\">CONSULTATION BPF IBM PHARMACEUTIQUE \u00b7 COR\u00c9E EVER-POWER<\/p>\n<h2 style=\"font-size: clamp(18px,3vw,28px); font-weight: 900; color: #fff; margin: 0 0 14px; letter-spacing: -0.5px;\">Planification de la qualification GMP KFDA cor\u00e9enne pour les conteneurs pharmaceutiques IBM\u00a0?<\/h2>\n<p style=\"font-size: 15px; color: #94a3b8; max-width: 520px; margin: 0 auto 28px; line-height: 1.65;\">Korea Ever-Power fournit la documentation BPF (Bonnes Pratiques de Fabrication) pour les machines IBM pharmaceutiques, incluant la certification machine, les sp\u00e9cifications des moules, un rapport dimensionnel d\u00e9taill\u00e9 avant livraison et une assistance \u00e0 la qualification des machines doubles. Notre \u00e9quipe d'application pharmaceutique \u00e9tablit un calendrier de qualification et une liste de contr\u00f4le CTF (Conditionnement Technique) lors de la consultation pr\u00e9alable \u00e0 la commande.<\/p>\n<p><a style=\"display: inline-flex; align-items: center; gap: 8px; background: #d97706; color: #fff; padding: 14px 36px; border-radius: 3px; text-decoration: none; font-weight: 800; font-size: 14px; letter-spacing: 0.5px; text-transform: uppercase;\" href=\"https:\/\/isbm-blow-molding.com\/fr\/contact-us\/\">Demande de consultation pharmaceutique IBM GMP <span style=\"font-size: 16px;\">\u2192<\/span><\/a><\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>&nbsp; REGULATORY GUIDE \u00b7 KOREAN KFDA GMP \u00b7 IBM PHARMACEUTICAL \u00b7 KOREA EVER-POWER Korean KFDA IBM Pharmaceutical Container GMP Guide Korean KFDA pharmaceutical container GMP qualification is the critical path item in every IBM pharmaceutical packaging project in Korea \u2014 longer than machine manufacture, longer than mould production, and independent of how quickly Korea Ever-Power [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-1090","post","type-post","status-publish","format-standard","hentry","category-technical-deep-dive"],"_links":{"self":[{"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/posts\/1090","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/comments?post=1090"}],"version-history":[{"count":1,"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/posts\/1090\/revisions"}],"predecessor-version":[{"id":1092,"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/posts\/1090\/revisions\/1092"}],"wp:attachment":[{"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/media?parent=1090"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/categories?post=1090"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/isbm-blow-molding.com\/fr\/wp-json\/wp\/v2\/tags?post=1090"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}